Inspections for the day of: Wednesday, June 12, 2019.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02391 Final6/10/20196/12/20196/12/2019 3:43:22 PMPFAIL
Customer will be home from 12-3 otherwise will need to reschedule for another date. Phone #: ###-#### Inspection requested via web by Devry King
- A/C coil ok
- need to provide homeowner with a co detector upstairs near bedrooms
MEC19-02418 Final6/10/20196/12/20196/12/2019 3:29:09 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace ac coil co ok
MEC19-02368 Final6/6/20196/12/20196/12/2019 3:17:32 PMPPASS
Please call John to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
- A/C coil co ok
MEC19-02440 Final6/11/20196/12/20196/12/2019 2:43:06 PMPFAIL
TENANT WORKS NIGHTS. HER NAME IS ALEXIS ; HER 18 YR OLD DAUGHTER LIBERTY SOMETIMES ANSWERS THE PHONE. PLEASE CALL AT LEAST 20 MIN B4 SHOWING UP ; COME AS LATE IN THE AFTERNOON AS YOU CAN FOR FINAL INSPECTION OF 80% FURNACE ; 13 SEER A/C Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
-furnace flue needs 6" clearances to combustibles or ran in b vent with 1" clearances
- condensate drain needs re ran in min 3/4" approved material
- A/C breaker size needs to be a 25amp
MEC18-03061 Final6/5/20196/12/20196/12/2019 2:30:56 PMPPASS
Phone #: ###-#### Inspection requested via web by Aaron Alandt
- duct blast ok
- final ok
MEC19-01289 Final6/11/20196/12/20196/12/2019 2:17:23 PMPFAIL
Please come as late as possible. Crawl work on this day and likely won''t be done until late afternoon. Call number listed to reach tech on site and see if it''s ready before arrival. Will reschedule if we need to but don''t want you to drive out if you''re going to be wasting your time. Thanks! Phone #: ###-#### Inspection requested via web by kelly Martin
- there was no gas pressure test set up
- inter mountain gas required piping at meter to be changed from what the homeowner and installer said. Gas piping that was changed was just a few fittings at the meter.
- need to add duct work to permit for the change out in the crawl
- need to pull a plumbing permit for the water heater
MEC19-02450 Final6/11/20196/12/20196/12/2019 1:53:54 PMPPASS
Please call Casey at ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Julie McMillan
- electric handler coil a/c co ok
MEC19-02442 Final6/12/20196/12/20196/12/2019 1:25:41 PMPNR
Please call Dave to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
-not ready
MEC19-02386 Final6/10/20196/12/20196/12/2019 1:08:46 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
MEC19-02363 Rough-in6/12/20196/12/20196/12/2019 11:26:23 AMPPASS
-R/I ok
MEC19-01787 Final6/12/20196/12/20196/12/2019 11:26:03 AMPPASS
Joe- bussiness closes at 3pm please arrive before Phone #: ###-####
- final ok
MEC19-02410 Final6/10/20196/12/20196/12/2019 10:31:34 AMAPASS
Request late morning final; contact Aaron (QHC) @ ###-#### or Kevin (QHC) @ Phone #: ###-#### Inspection requested via web by Kevin Pratley
- furnace ac coil co ok
MEC19-01022 Rough-in6/11/20196/12/20196/12/2019 10:16:59 AMAPASS
unit 122 Phone #: ###-#### Inspection requested via web by Nicholas Paige
- unit 122 R/I ok
MEC19-02363 Rough-in6/11/20196/12/20196/12/2019 9:59:08 AMAFAIL
Inspection requested via web by Lynn Johnston
- full nail plates for flex gas line
MEC19-02363 Pressure Test6/12/20196/12/20196/12/2019 9:58:41 AMAPASS
Inspection requested via web by Lynn Johnston
- 20lb gas pressure test ok
- tagged meter location
MEC19-00755 Final6/12/20196/12/20196/12/2019 9:19:32 AMAPASS
Im dropping off a copy of manual-J and air balance this morning 7:30. Thanks! Inspection requested via web by Floyd Floyd Peek
- final ok
MEC19-01675 Pressure Test6/11/20196/12/20196/12/2019 9:11:14 AMPPASS
field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney
- 20lb gas pressure test ok
- tagged meter location
MEC19-01675 Rough-in6/11/20196/12/20196/12/2019 9:10:48 AMPPASS
field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney
- R/I ok
MEC19-02272 Rough-in6/12/20196/12/20196/12/2019 8:53:25 AMAFAIL
Cover inspection
Phone #: ###-#### Inspection requested via web by Nicholas Paige
- need City approved prints onsite
MEC19-02403 Final6/11/20196/12/20196/12/2019 8:31:22 AMAPASS
Vern Pound is the homeowner. Call with ETA but he should be home. Phone #: ###-#### Inspection requested via web by kelly Martin
- furnace ac coil co ok
MEC19-02236 Final6/11/20196/12/20196/12/2019 8:22:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Scott Wickstrom
- final ok
MEC18-05219 Mec-Aging Inspection6/12/20196/12/20196/12/2019 7:57:17 AM DONE
This permit has not been active since being issued on 10/30/2018. If work is finished schedule inspection with the homeowner. Permit will expire at next aging inspection if not active by then. Permit will have to be issued again after being expired