PLM08-01371
| Water and/or Sewer | 6/13/2008 | 6/13/2008 | 6/13/2008 4:24:30 PM | P | PART |
|
|
contact is bob bivin ###-#### Phone #: ###-#### Internet Inspection Request from: Penny Smith 93 feet of sewer line from street up toward building test ok ok to cover
|
PLM08-01415
| Groundwork | 6/13/2008 | 6/13/2008 | 6/13/2008 3:36:04 PM | P | PASS |
|
|
Rocky Phone #: ###-####
|
PLM08-00816
| Final | 6/13/2008 | 6/13/2008 | 6/13/2008 3:18:41 PM | P | PART |
|
|
JOB CONTACT IS CHRIS BUSS Phone #: ###-#### Internet Inspection Request from: ADAM WARR need to have boiler drains in rest room by manager office protected with hose bib vacuum breaker,s under lav. need to have drinking fountain caulked at wall. need to have strainer installed on floor drain by manager office . need to correct kink in dishwasher drain hose at toe kick in cabnit. note chemical dispencer has been removed premius protection has been tested and certified. called contractor will recall when ready.
|
PLM08-00363
| Final | 6/13/2008 | 6/13/2008 | 6/13/2008 1:38:38 PM | P | PASS |
|
|
sky Phone #: ###-#### Note: please call ###-#### 1/2 hr prior to inspection (homeowner to get in)
|
PLM08-01037
| Final | 6/12/2008 | 6/13/2008 | 6/13/2008 1:22:46 PM | P | CANC |
|
|
Please, if possible, make this inspection towards the end of the day. Thank''s, Casey Spence Phone #: ###-#### Internet Inspection Request from: Steve Spence
|
PLM06-02370
| Plumbing Rough-in | 6/12/2008 | 6/13/2008 | 6/13/2008 12:12:47 PM | A | PART |
|
|
Gregory Phone #: ###-#### need to plmb in softner loop and drain note dwv and water test ok home owner to recall when ready
|
PLM08-01398
| Plumbing Rough-in | 6/12/2008 | 6/13/2008 | 6/13/2008 10:59:11 AM | A | PASS |
|
|
|
PLM08-01401
| Sprinkler (Final) | 6/12/2008 | 6/13/2008 | 6/13/2008 10:11:44 AM | A | PASS |
|
|
carol Phone #: ###-####
|
PLM08-01397
| Plumbing Rough-in | 6/12/2008 | 6/13/2008 | 6/13/2008 9:44:15 AM | A | PASS |
|
|
Sam Phone #: ###-####
|
PLM08-01340
| Plumbing Rough-in | 6/11/2008 | 6/13/2008 | 6/13/2008 9:31:49 AM | A | PASS |
|
|
Ready by 10:00AM Phone #: ###-#### Internet Inspection Request from: John Hensley
|
PLM08-01340
| DOC - Permit Finaled | 6/13/2008 | 6/13/2008 | 6/13/2008 9:31:40 AM | A | PASS |
|
|
Ready by 10:00AM Phone #: ###-#### Internet Inspection Request from: John Hensley
|
PLM08-01391
| Sprinkler (Final) | 6/13/2008 | 6/13/2008 | 6/13/2008 8:49:12 AM | A | PASS |
|
|
|
PLM08-01391
| Water and/or Sewer | 6/13/2008 | 6/13/2008 | 6/13/2008 8:49:01 AM | A | CANC |
|
|
permit address shows Hadlock Ct. It is on Hadlock St. according to the street sign. Phone #: ###-#### Internet Inspection Request from: Paul Kifer
|
PLM08-01404
| Water and/or Sewer | 6/12/2008 | 6/13/2008 | 6/13/2008 8:30:45 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Manda Love
|
PLM08-01404
| DOC - Permit Finaled | 6/13/2008 | 6/13/2008 | 6/13/2008 8:30:33 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Manda Love
|
PLM08-01386
| Water Heater Final | 6/12/2008 | 6/13/2008 | 6/13/2008 8:06:31 AM | A | PASS |
|
|
between 8:00 & 9:00 am please. if you cannot make that time please call scott at ###-####.(FISH ON)
|