ELE12-00548
| ELE-Aging Inspection | 6/13/2013 | 6/13/2013 | 6/17/2013 2:56:23 PM | | DONE |
|
|
Contractor will check job and call for final
|
ELE11-02678
| ELE-Aging Inspection | 6/13/2013 | 6/13/2013 | 6/14/2013 4:00:22 PM | | DONE |
|
|
waiting on owner
|
ELE12-00549
| ELE-Aging Inspection | 6/13/2013 | 6/13/2013 | 6/14/2013 3:48:47 PM | | DONE |
|
|
still under construction
|
ELE12-01529
| Final | 6/13/2013 | 6/13/2013 | 6/13/2013 4:05:03 PM | P | PASS |
|
|
>> Inspection requested via web by Judy Fisher Final ok
|
ELE13-01502
| Temporary Service | 6/13/2013 | 6/13/2013 | 6/13/2013 3:55:35 PM | P | NR |
|
|
Temp power pole for Taco Truck. Located in parking lot of Vernon Smith Law Offices on North/East Corner of S22nd/Main behind Red Lion. Phone #: ###-#### >> Inspection requested via web by Randy Fletcher Needs changed to permanent service and 2nd ground rod installed
|
ELE13-01482
| Temporary Service | 6/13/2013 | 6/13/2013 | 6/13/2013 3:34:27 PM | P | PASS |
|
|
Keith Phone #: ###-#### t/s o/h n ok
|
ELE13-01504
| Electrical Rough-In | 6/13/2013 | 6/13/2013 | 6/13/2013 3:09:21 PM | P | PASS |
|
|
home owner will be home for inspection Phone #: ###-#### >> Inspection requested via web by Terry Scott Kitchen island and back wall remodel rough in ok cover
|
ELE13-01455
| Temporary Service | 6/13/2013 | 6/13/2013 | 6/13/2013 2:47:26 PM | P | PASS |
|
|
Zach Phone #: ###-#### t/s o/h n ok
|
ELE13-01323
| Electrical Rough-In | 6/12/2013 | 6/13/2013 | 6/13/2013 2:35:16 PM | P | PASS |
|
|
They added a bath room, steam room in the basement. Phone #: ###-#### >> Inspection requested via web by Richard Corn basement hall, bath, and steam room
|
ELE13-01473
| Final | 6/13/2013 | 6/13/2013 | 6/13/2013 2:14:34 PM | P | FAIL |
|
|
This Will Be Ready This Afternoon. We Are Repairing A Riser That Is too Low. Please Call Me Thanks Dave Phone #: ###-#### >> Inspection requested via web by jason shifflett Reconnect ground for phone system
|
ELE13-01473
| Permanent Service | 6/13/2013 | 6/13/2013 | 6/13/2013 2:13:57 PM | P | PASS |
|
|
This Will Be Ready This Afternoon. We Are Repairing A Riser That Is too Low. Please Call Me Thanks Dave Phone #: ###-#### >> Inspection requested via web by jason shifflett p/s o/h rec ok
|
GCE13-00093
| GCE-Rough-In | 6/13/2013 | 6/13/2013 | 6/13/2013 1:52:46 PM | P | PASS |
|
|
Jay ###-#### call first Kitchen, storage, lighting, other than bar rough in ok cover
|
ELE13-01478
| Electrical Rough-In | 6/13/2013 | 6/13/2013 | 6/13/2013 10:30:16 AM | P | PASS |
|
|
TRENCH Phone #: ###-#### >> Inspection requested via web by Eric Brown Underground house to garage rough in ok cover
|
ELE13-01487
| Electrical Rough-In | 6/12/2013 | 6/13/2013 | 6/13/2013 10:17:19 AM | A | FAIL |
|
|
Please call Asher Sears, the electrician, if any questions Phone #: ###-#### >> Inspection requested via web by brad williams 300.4- NMB cable shall be secured at least 1 1/4" from framing member edge. 334.30 Flat cables shall not be sedured on edge. HVAC classifies 18" above floor in garage as hazardous location, move recepticals up to 18" minimum to bottom.
|
ELE13-01450
| Electrical Rough-In | 6/12/2013 | 6/13/2013 | 6/13/2013 9:47:21 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Kitchen remodel, check j-box N.E. coner down low for accessibility. Rough in ok cover
|
ELE12-02982
| Conference | 6/12/2013 | 6/13/2013 | 6/13/2013 9:33:25 AM | A | DONE |
|
|
tony Phone #: ###-#### Discussed electrical for fire pumps that have moved from basement to 1st floor
|
ELE11-02806
| Final | 6/12/2013 | 6/13/2013 | 6/13/2013 8:40:05 AM | A | PASS |
|
|
last of the project... surface mounted lights in the basement/parking garage call mike 1/2 hour prior if needed ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Basye Project complete Final ok
|