ELE13-02488
| Final | 6/11/2014 | 6/13/2014 | 6/13/2014 2:00:07 PM | P | PASS |
|
|
Home owner will be home for access. Phone #: ###-#### >> Inspection requested via web by Jay Symonds ok final
|
ELE14-01497
| Permanent Service | 6/12/2014 | 6/13/2014 | 6/13/2014 1:12:25 PM | P | PASS |
|
|
Please call Calvin if you have any questions. Thank you. Phone #: ###-#### >> Inspection requested via web by Clay Morgan shall check grounding, ri for rest of house p/s o/h rec ok
|
ELE14-01524
| Rough-In Permanent Service | 6/12/2014 | 6/13/2014 | 6/13/2014 12:26:28 PM | A | FAIL |
|
|
any questions I have a crew in the home next door, thx, TW., Phone #: ###-#### >> Inspection requested via web by Stephen Kren checked with contractor, left correction notice, NEC 334.23 shall protect nm cable within 6' of attic access, 210.52(A)(1)(2) shall install receptacle in 2' wall, 300.4(A) shall provide steel plate if edge of bored hole is less than 1 1/4" from edge of frqaming member, BCC shall post address or job id sticker, NOTE: no u/g from house to garage installed or inspected
|
ELE14-01514
| Permanent Service | 6/13/2014 | 6/13/2014 | 6/13/2014 11:45:41 AM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey p/s o/h rec ok
|
ELE14-01284
| Electrical Rough-In | 6/12/2014 | 6/13/2014 | 6/13/2014 11:37:58 AM | A | FAIL |
|
|
Cover inspection for basement Phone #: ###-#### >> Inspection requested via web by Steve Craig called, met builder, shall staple nm within 12" of box, shall not use damaged nm, shall not staple nm on edge, shall add receptacle in 10' hall, shall secure nm out of can lights
|
ELE14-01064
| Final | 6/12/2014 | 6/13/2014 | 6/13/2014 10:50:24 AM | A | NH |
|
|
mike Phone #: ###-#### called, left message, left card
|
ELE14-00979
| Final | 6/11/2014 | 6/13/2014 | 6/13/2014 10:20:02 AM | A | PASS |
|
|
Home owner will be home. Kitchen, Dining, Pantry, Utility. Phone #: ###-#### >> Inspection requested via web by Mike Cole ok final
|
ELE14-01521
| Electrical Rough-In | 6/11/2014 | 6/13/2014 | 6/13/2014 10:12:13 AM | A | PASS |
|
|
For access please call Ed 1/2 hr prior to inspection. ###-#### >> Inspection requested via web by Terry Scott bath ri ok
|
ELE14-01516
| Permanent Service | 6/12/2014 | 6/13/2014 | 6/13/2014 9:41:21 AM | A | PASS |
|
|
Call before you get there 30 minutes if possible so I can get owner there to open truck Phone #: ###-#### >> Inspection requested via web by robert feller met contractor, shall not connect taco truck until completely re-wired, told if no inspection on truck, will have meter pulled, p/s o/h n ok
|
ELE14-00824
| Electrical Rough-In | 6/12/2014 | 6/13/2014 | 6/13/2014 9:13:45 AM | A | PASS |
|
|
dragan Phone #: ###-#### ok cover patio cover
|
ELE14-01540
| Final | 6/12/2014 | 6/13/2014 | 6/13/2014 8:31:34 AM | A | PASS |
|
|
Lockbox 8008. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan ok final
|
ELE14-01540
| Permanent Service | 6/12/2014 | 6/13/2014 | 6/13/2014 8:23:12 AM | A | PASS |
|
|
Lockbox 8008. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan p/s u/g rec ok
|