ELE17-01312
| Electrical Rough-In | 6/13/2017 | 6/13/2017 | 6/13/2017 4:15:53 PM | P | FAIL |
|
|
Shall pull seperate permit for temp pole. 210.52- Receptacle outlet needed with 6' of refer, outlet needed 2' wall by back door, outlet needed next to slider for 2 fixed panels. 300.4 nail plate up high by back door and windows. 310.15(B)(3)- Too many current carrying (10) conductors 1/2 wall by stairs. (9) max. 334.30- Powder bath outlet NM shall secure with in 12" of box. 334.12- NM shall not be installed where subject to physical damage. stair above runner. Homeruns run thru truss in garage ceiling. Truss company will issue how to proceed. Insulators started to insulate entry way, when asked to stop became difficult. Had conversation with general contractor told job is not approved for cover and shall not cover.
|
ELE17-00768
| Final | 6/13/2017 | 6/13/2017 | 6/13/2017 3:15:26 PM | P | PASS |
|
|
door code 9413 Phone #: ###-#### Inspection requested via web by cal crosby Final ok
|
ELE17-00844
| Electrical Rough-In | 6/13/2017 | 6/13/2017 | 6/13/2017 2:44:52 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks Wrong job called in
|
ELE17-00584
| Final | 6/12/2017 | 6/13/2017 | 6/13/2017 11:27:20 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Emmet Bushman Final ok
|
ELE16-01667
| Final | 6/12/2017 | 6/13/2017 | 6/13/2017 10:39:56 AM | A | PEND |
|
|
Re-inspect 301 , 302 , 303 ,304 , 402 , 403 , 404 and finals on 401 , 405 Phone #: ###-#### Inspection requested via web by Tom Betty 401 had receptacles not working in family, and halls. 301 thru 304 and 402 thru 405 checked out OK. TCO pending stairways, out egress, core and shell areas approval
|
ELE17-01826
| Electrical Rough-In | 6/13/2017 | 6/13/2017 | 6/13/2017 10:12:34 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt Inspection cancelled from web by: John VanZandt
|
ELE17-01693
| Rough-In Permanent Service | 6/12/2017 | 6/13/2017 | 6/13/2017 9:26:14 AM | A | PASS |
|
|
Ready now thank you. Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE17-01336
| Final | 6/13/2017 | 6/13/2017 | 6/13/2017 9:09:41 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by steve ragan Inspection cancelled from web by: steve ragan
|