Inspections for the day of: Wednesday, June 14, 2006.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM06-00362 Final6/14/20066/14/20066/14/2006 3:53:10 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Steve Spence 1. need main shut off before double check in mechanical room. 2. have double check tested and certified. 3. caulk mop sink at wall and floor. 4. need to provide 120 need hot water limitation for public laves. 5.need open front seat,s on water closet,s. 6. need expansion tank installed on water heater. 7. need to install water heater pan & drain for water heater in overhead 8. need to have occupancy sign off card on job site. left correction notice with general contractor on site
PLM05-04309 Plumbing Rough-in6/14/20066/14/20066/14/2006 2:38:36 PMAPART
Scheduled by a contractor via Hello! on 6/14/2006 at 7:12:35 AM. Contact: ###-####. TEST FAILED on third floor under floor DWV on south west side of building need to correct leak and recall when ready
PLM06-01998 Sprinkler (Final)6/13/20066/14/20066/14/2006 1:28:23 PMAPASS
###-####
PLM06-01596 Groundwork6/13/20066/14/20066/14/2006 10:45:39 AMAPART
tom - Note: top out and groundwork; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ground work and top out for DWV ONLY for pharmacy area test ok
PLM06-01997 Water and/or Sewer6/13/20066/14/20066/14/2006 10:26:42 AMAPART
water line only test ok ok to cover
PLM06-01807 Final6/13/20066/14/20066/14/2006 10:00:07 AMAPART
ready for final inspection; Phone #: ###-#### Internet Inspection Request from: Jon VanVleet repipe water line in over head and insulate and provide heat tent for final
PLM06-01983 Water and/or Sewer6/13/20066/14/20066/14/2006 9:58:06 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Scott Wickstrom
PLM06-01983 DOC - Permit Finaled6/14/20066/14/20066/14/2006 9:57:51 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Scott Wickstrom
PLM06-01338 Groundwork6/13/20066/14/20066/14/2006 8:59:33 AMAPASS
BOB; Phone #: ###-#### Internet Inspection Request from: James Stanford