Inspections for the day of: Tuesday, June 14, 2011.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-02428 ELE-Aging Inspection6/14/20116/14/20116/15/2011 12:20:54 PM DONE
still under construction
ELE10-00018 ELE-Aging Inspection6/14/20116/14/20116/15/2011 12:20:05 PM DONE
still under construction
ELE08-02423 Electrical Rough-In6/13/20116/14/20116/14/2011 3:02:24 PMPCANC
jason Phone #: ###-#### contractor called, not ready, will call for later
ELE11-01237 Electrical Rough-In6/14/20116/14/20116/14/2011 3:01:23 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Andy Derrick ri ok
ELE11-01204 Temporary Service6/14/20116/14/20116/14/2011 2:08:48 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson t/s u/g n ok
ELE11-01190 Rough-In Permanent Service6/14/20116/14/20116/14/2011 1:55:56 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson ri ok, p/s u/g n ok
ELE11-01166 Electrical Rough-In6/13/20116/14/20116/14/2011 12:56:12 PMPFAIL
Call 30min prior----Arthur Phone #: ###-#### met owner, left correction notice- BCC shall change room count to 5, all make-up shall be done, NEC 352.30 shall strap pvc within 3' of panel,110.26(F) there shall be no foreign piping in dedicated panel space, 334.23 shall protect wiring within 6' of attic access, 210.52 shall provide receptacles per code section, 300.4(A) edge of bored holes shall be within 1 1/4" of edge of framing member, 300.15 covers shall be accessible
ELE11-01210 Final6/13/20116/14/20116/14/2011 10:11:30 AMAPASS
rex - please call 1/2 hr prior Phone #: ###-#### ok final
ELE11-01232 Electrical Rough-In6/13/20116/14/20116/14/2011 8:59:12 AMAPASS
This new Cool Ped phone cabinet is the one furthest from the power pedestal. The one closest to the power pedestal was existing.
Thanks!!! Dan. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell ri ok
ELE11-01232 Final6/14/20116/14/20116/14/2011 8:58:58 AMAPASS
This new Cool Ped phone cabinet is the one furthest from the power pedestal. The one closest to the power pedestal was existing.
Thanks!!! Dan. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell ok final
ELE11-01236 Final6/14/20116/14/20116/14/2011 8:26:50 AMAFAIL
this for wall cover and ceiling cover Phone #: ###-#### >> Inspection requested via web by Don Lustig talked with contractor to remove lv wiring, cover boxes, put on outlet and switch covers