Inspections for the day of: Tuesday, June 14, 2016.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02995 ELE-Aging Inspection6/14/20166/14/20166/15/2016 3:44:43 PM PASS
Waiting on owner
ELE16-00925 Electrical Rough-In6/13/20166/14/20166/14/2016 3:47:32 PMPPASS
Lee-would like late pm if poss Phone #: ###-#### Phase 2 entry walls rough in ok cover
ELE16-01874 Electrical Rough-In6/13/20166/14/20166/14/2016 3:19:50 PMPPASS
Please inspect underground for cover. Phone #: ###-#### Inspection requested via web by Spencer McLean
Underground for verizon meter from in ground box to south fence rough in ok cover
ELE16-01483 Conference6/13/20166/14/20166/14/2016 2:38:25 PMPDONE
Please contact Greg 30 min prior to arrival. This is for a consultation. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker
Discussed the ampacity of feeders from basement to each unit. Quoted NEC 310.15(A)(2)exeption, if less than 10' or 10% of circuit length is enclosed by thermal insulation adjustment factor of using 60 degree column shall not apply. General contractor to assist with uninsulated path to help with costs of wiring.
ELE16-01875 Temporary Service6/14/20166/14/20166/14/2016 1:53:06 PMPPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson
t/s u/g n ok
ELE16-01653 Electrical Rough-In6/14/20166/14/20166/14/2016 12:59:59 PMPPASS
2nd floor ceiling rough-in Phone #: ###-#### Inspection requested via web by JENNY EMEL
2nd floor corridor grid rough in ok cover
ELE16-00089 Electrical Rough-In6/13/20166/14/20166/14/2016 12:40:23 PMPPASS
Call Bob for inspection of 5th floor IT room exterior wall. Phone #: ###-#### Inspection requested via web by Rafael Castillo
As noted and marked on print wall rough in ok cover
ELE15-03901 Electrical Rough-In6/13/20166/14/20166/14/2016 12:34:11 PMAPASS
Call Pierce for ceiling inspection of 7th floor server room area. Phone #: ###-#### Inspection requested via web by Rafael Castillo
7th floor server room center grid tiles ok to install for equipment.
ELE15-01617 Electrical Rough-In6/13/20166/14/20166/14/2016 11:13:56 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
1st floor entry soffits and east fireplace wall, 4th floor student desk soffit and bathroom hardlids rough in ok cover
ELE16-01870 Electrical Rough-In6/13/20166/14/20166/14/2016 10:32:54 AMAPASS
Bonding Inspection Phone #: ###-#### Inspection requested via web by Louis Keller
Stubs an on all 4 corners, light, stub for cover rough in ok cover
ELE16-01334 Final6/13/20166/14/20166/14/2016 10:02:41 AMAFAIL
Good morning, This will be a final for this permit please. Contact is David Joseph ###-####. Please give him a call if you have any questions as he will not be o the job site. Thank you and have a super day! Phone #: ###-#### Inspection requested via web by Laura Longshaw
210.8(B)-All 120 volt 20 amp receptacle outlets located within 6' of a sink or basin shall have GFCI protection.
110.3- Twin breaker modified to be installed in a panel not listed for twin breakers.
ELE16-01264 Final6/14/20166/14/20166/14/2016 9:38:48 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ESC16-00306 Random Inspection6/14/20166/14/20166/14/2016 9:38:15 AMPPASS
Landscape not started yet, clean job site
ELE16-01154 Final6/14/20166/14/20166/14/2016 9:24:42 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ESC16-00280 Random Inspection6/14/20166/14/20166/14/2016 9:23:55 AMPPASS
Front landscape complete clean job site
ELE16-00901 Electrical Rough-In6/13/20166/14/20166/14/2016 8:26:18 AMAPASS
Dan ###-#### phase 2 CT wall rough in ok cover
ELE16-00901 Electrical Rough-In6/13/20166/14/20166/13/2016 4:14:46 PMACANC
Dan ###-####