PLM15-02904
| PLM-Aging Inspection | 6/14/2016 | 6/14/2016 | 6/16/2016 9:55:25 AM | | FAIL |
|
|
>backflow still needs to be certified in order to close this permit.
|
PLM16-02080
| Plumbing Rough-in | 6/13/2016 | 6/14/2016 | 6/14/2016 3:43:41 PM | P | CANC |
|
|
MEL IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER >cancel per Mel
|
PLM16-02141
| Final | 6/14/2016 | 6/14/2016 | 6/14/2016 3:40:37 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Field >tub/sh swap out, ri trim, ok
|
PLM16-02141
| Water and/or Sewer | 6/14/2016 | 6/14/2016 | 6/14/2016 3:40:18 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Chris Field
|
PLM16-02132
| Final | 6/13/2016 | 6/14/2016 | 6/14/2016 3:20:30 PM | P | PASS |
|
|
Ryan Phone #: ###-#### >PVB ok
|
PLM16-02117
| Water and/or Sewer | 6/13/2016 | 6/14/2016 | 6/14/2016 1:31:22 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Darren Wood
|
PLM16-02118
| Water and/or Sewer | 6/13/2016 | 6/14/2016 | 6/14/2016 1:31:16 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darren Wood
|
PLM16-02118
| DOC - Permit Finaled | 6/14/2016 | 6/14/2016 | 6/14/2016 1:31:13 PM | P | PASS |
|
|
|
PLM16-02001
| Plumbing Rough-in | 6/13/2016 | 6/14/2016 | 6/14/2016 11:15:56 AM | A | PASS |
|
|
Phone #: ###-#### x303 Inspection requested via web by Erin Whiting
|
PLM16-02119
| DOC - Permit Finaled | 6/14/2016 | 6/14/2016 | 6/14/2016 10:20:45 AM | P | PASS |
|
|
|
PLM16-02119
| Water and/or Sewer | 6/13/2016 | 6/14/2016 | 6/14/2016 10:20:20 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bruce Scott
|
PLM16-02086
| Water and/or Sewer | 6/13/2016 | 6/14/2016 | 6/14/2016 10:00:25 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darren Wood >water service needs to be 1 1/2" dou to length and fixture unit demand. >when water and sewer are in the same trench sewer must be pvc sch 40 entire length. >bed all sewer pipe, not just piles. >expose tie in, is has sluffed off and covered. >cleanout from house exceeds 100'
|
PLM16-02079
| Water Heater Final | 6/8/2016 | 6/14/2016 | 6/14/2016 9:12:37 AM | A | PASS |
|
|
Homeowner requests morning inspection. Please call when en route - Contact is Beth Purdy Phone #: ###-#### Inspection requested via web by JEREMY LINK
|
PLM16-02134
| DOC - Permit Finaled | 6/14/2016 | 6/14/2016 | 6/14/2016 8:41:39 AM | P | PASS |
|
|
|
PLM16-02134
| Water and/or Sewer | 6/13/2016 | 6/14/2016 | 6/14/2016 8:41:09 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by matt ford
|
PLM16-02125
| Final | 6/13/2016 | 6/14/2016 | 6/14/2016 8:23:06 AM | A | PASS |
|
|
Please call at least 30 minutes prior to inspection so Scott can get home. ###-####. He works about 20 - 30 minutes from home. Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
PLM16-00021
| PLM-Aging Inspection | 6/14/2016 | 6/14/2016 | 6/14/2016 8:00:52 AM | | FAIL |
|
|
no insp request
|
PLM16-00022
| PLM-Aging Inspection | 6/14/2016 | 6/14/2016 | 6/14/2016 8:00:06 AM | | FAIL |
|
|
no further inspections have been scheduled.
|