Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM15-02904 PLM-Aging Inspection6/14/20166/14/20166/16/2016 9:55:25 AM FAIL
>backflow still needs to be certified in order to close this permit.
PLM16-02080 Plumbing Rough-in6/13/20166/14/20166/14/2016 3:43:41 PMPCANC
MEL IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
>cancel per Mel
PLM16-02141 Final6/14/20166/14/20166/14/2016 3:40:37 PMPPASS
Phone #: ###-#### Inspection requested via web by Chris Field
>tub/sh swap out, ri trim, ok
PLM16-02141 Water and/or Sewer6/14/20166/14/20166/14/2016 3:40:18 PMPCANC
Phone #: ###-#### Inspection requested via web by Chris Field
PLM16-02132 Final6/13/20166/14/20166/14/2016 3:20:30 PMPPASS
Ryan Phone #: ###-####
>PVB ok
PLM16-02117 Water and/or Sewer6/13/20166/14/20166/14/2016 1:31:22 PMPNR
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM16-02118 Water and/or Sewer6/13/20166/14/20166/14/2016 1:31:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM16-02118 DOC - Permit Finaled6/14/20166/14/20166/14/2016 1:31:13 PMPPASS
PLM16-02001 Plumbing Rough-in6/13/20166/14/20166/14/2016 11:15:56 AMAPASS
Phone #: ###-#### x303 Inspection requested via web by Erin Whiting
PLM16-02119 DOC - Permit Finaled6/14/20166/14/20166/14/2016 10:20:45 AMPPASS
PLM16-02119 Water and/or Sewer6/13/20166/14/20166/14/2016 10:20:20 AMAPASS
Phone #: ###-#### Inspection requested via web by Bruce Scott
PLM16-02086 Water and/or Sewer6/13/20166/14/20166/14/2016 10:00:25 AMAFAIL
Phone #: ###-#### Inspection requested via web by Darren Wood
>water service needs to be 1 1/2" dou to length and fixture unit demand.
>when water and sewer are in the same trench sewer must be pvc sch 40 entire length.
>bed all sewer pipe, not just piles.
>expose tie in, is has sluffed off and covered.
>cleanout from house exceeds 100'
PLM16-02079 Water Heater Final6/8/20166/14/20166/14/2016 9:12:37 AMAPASS
Homeowner requests morning inspection. Please call when en route - Contact is Beth Purdy Phone #: ###-#### Inspection requested via web by JEREMY LINK
PLM16-02134 DOC - Permit Finaled6/14/20166/14/20166/14/2016 8:41:39 AMPPASS
PLM16-02134 Water and/or Sewer6/13/20166/14/20166/14/2016 8:41:09 AMAPASS
Phone #: ###-#### Inspection requested via web by matt ford
PLM16-02125 Final6/13/20166/14/20166/14/2016 8:23:06 AMAPASS
Please call at least 30 minutes prior to inspection so Scott can get home. ###-####. He works about 20 - 30 minutes from home. Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM16-00021 PLM-Aging Inspection6/14/20166/14/20166/14/2016 8:00:52 AM FAIL
no insp request
PLM16-00022 PLM-Aging Inspection6/14/20166/14/20166/14/2016 8:00:06 AM FAIL
no further inspections have been scheduled.