BLD00-00977
| BLD-Framing/Rough-in | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | FAIL |
|
|
John ###-#### C/N, truss corr., F/P insp. 6/15/00 1:47:11 PM
|
BLD00-00408
| BLD-Energy code compliance | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 06/14/2000 at 11:39:39. Contact: ###-####.
|
BLD00-01222
| BLD-Framing/Rough-in | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 06/14/2000 at 12:41:55. Contact: ###-####. Energy pass 6/15/00 1:47:30 PM
|
BLD00-01310
| BLD-Framing/Rough-in | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | PART |
|
|
elliot ###-#### shear wall Shear ok 6/15/00 1:46:44 PM
|
MEC00-01991
| Pressure Test | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 06/14/2000 at 15:51:25. Contact: ###-####.
|
BLD00-00035
| BLD-Foundation | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | PASS |
|
|
###-####
|
BLD00-00826
| BLD-Final | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | PASS |
|
|
###-#### C/C #19541 6/15/00 1:47:37 PM
|
MEC00-01530
| Final | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 06/14/2000 at 17:09:44. Contact: ###-####.
|
MEC00-01588
| Final | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 06/14/2000 at 17:10:42. Contact: ###-####.
|
BLD99-02317
| BLD-Final | 6/14/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 06/14/2000 at 17:46:43. Contact: ###-####. OK for temp. occ.- C/N need req. signatures for perm. occ. within 90 days letter from special insp. 6/16/00 8:53:25 AM
|
BLD00-01289
| BLD-Framing/Rough-in | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PART |
|
|
shear wall cole ###-#### Shear ok 6/16/00 8:54:10 AM
|
BLD99-02307
| BLD-Footing | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PART |
|
|
###-#### darren F/P not shown on appr. plot plan contr. notified. 6/16/00 8:54:29 AM
|
BLD00-01455
| BLD-Footing | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PART |
|
|
###-#### Unable to determine front setback contractor notified 6/16/00 8:53:43 AM
|
BLD00-01449
| BLD-Footing | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PART |
|
|
late pm ###-####
|
BLD00-01448
| BLD-Framing/Rough-in | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PASS |
|
|
russ ###-####
|
BLD00-01448
| BLD-Energy code compliance | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | FAIL |
|
|
russ ###-#### NR 6/16/00 8:54:44 AM
|
BLD00-00864
| BLD-Framing/Rough-in | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PASS |
|
|
###-####
|
BLD00-00864
| BLD-Energy code compliance | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PASS |
|
|
###-####
|
BLD00-01068
| BLD-Wall cover | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 06/15/2000 at 10:01:11. Contact: ###-####. Shear ok 6/16/00 8:53:49 AM
|
BLD00-01177
| BLD-Framing/Rough-in | 6/15/2000 | 6/15/2000 | 6/15/2000 12:00:00 AM | P | PART |
|
|
###-#### shear nail Shear ok 6/16/00 8:55:49 AM
|