Inspections for the day of: Thursday, June 15, 2006.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02209 Temporary Service6/15/20066/15/20066/15/2006 4:25:51 PMPFAIL
###-#### - joe called, left corr notice, nec 312.5 all conductors entering enclosures shall have abrasion protection, 250.24 gec shall connect to grounded conductor terminal,BCC job id sticker shall be posted
ELE06-02210 Temporary Service6/15/20066/15/20066/15/2006 3:58:31 PMPFAIL
###-#### - joe called, left corr notice, nec 312.5 all conductors entering enclosures shall have abrasion protection, 250.24 gec shall connect to grounded conductor terminal, 110.14(A) gec terminal shall be tight for thouroughly good connection, BCC job id sticker shall be posted,
ELE06-02208 Rough-In Permanent Service6/15/20066/15/20066/15/2006 3:52:37 PMPFAIL
###-#### - joe called, left corr notice, nec 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing member, 210.52(A)(1) recpts shall not be over 6' from each other measured along the floor line in any wall space,BCC all make-up shall be done,boxes installed for entry and bath,panel shall be put in a safe condition with cover
ELE06-02021 Electrical Rough-In6/15/20066/15/20066/15/2006 3:07:05 PMPPASS
randy - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ric ok
ELE06-02022 Electrical Rough-In6/15/20066/15/20066/15/2006 2:57:18 PMPPASS
randy - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ric ok
ELE06-00784 Final6/15/20066/15/20066/15/2006 2:01:55 PMPFAIL
PAUL; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy called contr, left corr notice, nec 210.8(A) gfci recpts in kitchen shall operate, garage gfci shall show correct wiring, 314.23(C) box and recpt at top of stairs shall be securely mounted, 110.13(A) all panel cover screws shall be installed
ELE06-00416 Electrical Rough-In6/15/20066/15/20066/15/2006 1:38:36 PMPNR
PLEASE INSPECT FOR ABOVE CIELING ROUGH IN THIS AFTERNOON 6/15/06. CALL TODD HALL AT THE ABOVE NUMBER WITH QUESTIONS OR THE OFFICE AT ###-####; Phone #: ###-#### Internet Inspection Request from: todd hall open clg boxes, no lv pulled
ELE06-02171 Final6/13/20066/15/20066/15/2006 1:08:30 PMPNR
Stu; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt elect not done
ELE06-02215 Electrical Rough-In6/15/20066/15/20066/15/2006 12:08:11 PMPCANC
Rick; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt see rip
ELE06-02215 Rough-In Permanent Service6/15/20066/15/20066/15/2006 12:06:32 PMPPASS
Rick; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ric ok, p/s u/g n ok
ELE06-00907 ELE-Aging Inspection6/15/20066/15/20066/15/2006 11:13:01 AM DONE
see final
ELE06-00907 Final6/15/20066/15/20066/15/2006 11:12:41 AMAPASS
looked at sign ok to final
ELE05-03277 ELE-Aging Inspection6/15/20066/15/20066/15/2006 11:03:57 AM DONE
suc
ELE06-01922 Electrical Rough-In6/14/20066/15/20066/15/2006 10:57:25 AMADONE
jerry Note: swimming pool; equal potential plain Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok was done 6-12-06
ELE06-02202 Electrical Rough-In6/14/20066/15/20066/15/2006 10:33:59 AMPPASS
###-####, homeowner & contractor''''s # is the ###-####; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ric ok
ELE06-02187 Temporary Service6/15/20066/15/20066/15/2006 10:19:56 AMAPASS
Scheduled by a contractor via Hello! on 6/15/2006 at 6:36:42 AM. Contact: ###-####. t/s u/g n ok
ELE06-02194 Temporary Service6/15/20066/15/20066/15/2006 10:05:58 AMAPASS
Scheduled by a contractor via Hello! on 6/15/2006 at 6:38:25 AM. Contact: ###-####. t/s u/g n ok
ELE06-02177 Temporary Service6/15/20066/15/20066/15/2006 10:04:23 AMAPASS
Scheduled by a contractor via Hello! on 6/15/2006 at 6:39:43 AM. Contact: ###-####. t/s u/g n ok
ELE06-02180 Temporary Service6/14/20066/15/20066/15/2006 9:43:26 AMAPASS
please contact Pat for temp power service, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters corr made, t/s u/g n ok
ELE06-01628 Final6/14/20066/15/20066/15/2006 9:09:17 AMACANC
contr said will recall
ELE06-00113 Electrical Rough-In6/15/20066/15/20066/15/2006 9:08:02 AMAPART
lobby bath walls, 6th stairwell walls ok to cover
ELE05-03958 Final6/14/20066/15/20066/15/2006 8:59:19 AMAPASS
larry - call for access prior to insp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to final
ELE06-01262 Final6/14/20066/15/20066/15/2006 8:41:14 AMAPASS
LOS BETOS IS READY FOR FINAL RE-INSPECTION. THANKS; Phone #: ###-#### Internet Inspection Request from: Barry Kendall corr made, ok to final, signed occ card