Inspections for the day of: Friday, June 15, 2018.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-02746 Final6/15/20186/15/20186/15/2018 4:18:58 PMPPASS
home owner called back for inspection

- A/C coil ok
MEC18-01125 Final6/15/20186/15/20186/15/2018 3:55:43 PMPPASS
call general contractor Matt Phillips for access ###-#### Phone #: ###-#### Inspection requested via web by Jon VanderStelt
MEC18-02734 Rough-in6/14/20186/15/20186/15/2018 3:55:13 PMPPASS
Rough in and pressure test Inspection requested via web by David Petsche
MEC18-02315 Rough-in6/14/20186/15/20186/15/2018 3:01:51 PMPNR
PLEASE COMPLETE FULL SYSTEM HVAC FOR NEW HOME Phone #: ###-#### Inspection requested via web by Andrea Creek- crawl not finished- need to make sure to get inert tape on gas line as well
MEC18-02315 Pressure Test6/14/20186/15/20186/15/2018 3:00:54 PMPPASS
PLEASE COMPLETE FULL SYSTEM HVAC FOR NEW HOME Phone #: ###-#### Inspection requested via web by Andrea Creek- 20 lb gas pressure test ok- need inert tape on gas line penetration at meter
MEC18-01260 Pressure Test6/15/20186/15/20186/15/2018 2:20:43 PMPPASS
Field Super;Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- 60 lb gas pressure test ok
MEC17-05709 Final6/15/20186/15/20186/15/2018 1:25:51 PMPPASS
Garage code is 7060. Please call with any questions or concerns. Thank you Phone #: ###-#### Inspection requested via web by ted roy
- lineset rips fixed and okp- exhaust fans ok- ductblast report onsite- final ok
MEC18-02746 Final6/14/20186/15/20186/15/2018 1:15:03 PMPNH
ERIC ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- not home left notice on front door
MEC17-01759 DOC - Permit Finaled6/15/20186/15/20186/15/2018 1:07:02 PMPPASS
final ok home owners let me in
MEC17-01759 Mec-Aging Inspection6/15/20186/15/20186/15/2018 1:06:28 PM PASS
uv protection ok- breaker size ok- water tight conduit ok
MEC17-03083 Mec-Aging Inspection6/15/20186/15/20186/15/2018 12:56:16 PM NH
left notice on front door
MEC18-02579 Final6/15/20186/15/20186/15/2018 12:43:58 PMPPASS
This unit is a unit we swapped with an old unit they had in storage. Please contact Brandon with any questions. Phone #: ###-#### Inspection requested via web by Ted Dumont-RTU change out final ok
MEC18-02464 Final6/11/20186/15/20186/15/2018 12:07:37 PMAFAIL
LATE AM PRESSURE TEST IF POSSIBLE PLEASE
INSTALLER: ALBERTO ###-####
THANK YOU Phone #: ###-#### Inspection requested via web by Aaron Alandt- Man J. needs to be approved by the city with fresh air- will also need to see air balance report and duct blast- need to also update permit with other for new ducting and pay fee
MEC18-02464 Rough-in6/15/20186/15/20186/15/2018 12:00:03 PMPPASS
new duct work in crawl space R/I ok
MEC18-02464 Pressure Test6/11/20186/15/20186/15/2018 11:57:12 AMAPASS
LATE AM PRESSURE TEST IF POSSIBLE PLEASE
INSTALLER: ALBERTO ###-####
THANK YOU Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20 lb gas pressure test ok- R/I of gas line ok aswell- stickered gas line for gas company
MEC18-01459 DOC - Permit Finaled6/15/20186/15/20186/15/2018 11:22:31 AMPPASS
make up is upstairs final ok
MEC18-01459 Final6/14/20186/15/20186/15/2018 11:02:30 AMAFAIL
Phone #: ###-#### Inspection requested via web by Krista Boss- need make air for large range exhaust hood that is over 400 cfm
MEC18-02729 Final6/14/20186/15/20186/15/2018 10:43:10 AMACANC
homeowner- Jim Latva ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake- should have been a R/I
MEC18-02729 Rough-in6/15/20186/15/20186/15/2018 10:42:43 AMPPASS
homeowner- Jim Latva ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake- condensate drain fixed- nail plates installed- will want to see condensate drain 90 down outside at final- bathroom exhaust fan ducting R/I ok- I changed the final that was called in to a R/I and cancelled final
MEC18-02618 Rough-in6/15/20186/15/20186/15/2018 10:25:01 AMPCANC
ok to pour concrete - please call Brett ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
MEC18-02696 Rough-in6/14/20186/15/20186/15/2018 10:19:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace R/I ok
MEC18-01413 Final6/14/20186/15/20186/15/2018 10:07:53 AMAPASS
Access # 1993 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- air balance report onsite ok- final ok
MEC18-01125 Final6/14/20186/15/20186/15/2018 9:44:46 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jon VanderStelt- no access to building
MEC18-02240 Final6/13/20186/15/20186/15/2018 9:44:11 AMAPASS
Please call Jake Sauser prior to inspection at ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
MEC18-01849 Rough-in6/14/20186/15/20186/15/2018 8:58:49 AMAPASS
MIKE IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- 60lb gas pressure test ok- R/I ok