Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-01889 Rough-In Permanent Service6/8/20206/15/20206/15/2020 2:22:18 PMPPASS
Electrician: Chris Avery Phone #: ###-#### Inspection requested via web by Same Electric Service upgrade only. p/s o/h rec ok
ELE20-02021 Final6/15/20206/15/20206/15/2020 2:05:21 PMPPASS
Phone #: ###-#### Inspection requested via web by Calvin Bohrer Final ok
ELE20-02021 Electrical Rough-In6/15/20206/15/20206/15/2020 1:51:54 PMPPASS
Phone #: ###-#### Inspection requested via web by Calvin Bohrer All on exterior of house. Rough in ok
ELE20-00121 Final6/15/20206/15/20206/15/2020 1:43:21 PMPFAIL
Bill *screened* Phone #: ###-####
Correction not complete.
110.3- In garage receptacle marked welder is rated for 30 amp 125 volt for recreational vehicle use only, 2-pole 30 labelled supplies power.
ELE19-01226 Final6/13/20206/15/20206/15/2020 1:30:50 PMPPASS
NOT ON SITE. BACK DOOR OPEN. CALL WITH QUESTIONS. Phone #: ###-#### Inspection requested via web by Garrett Collins No card posted. Final ok
ELE20-00016 Final6/13/20206/15/20206/15/2020 11:19:00 AMPCANC
lockbox on front door. Code is 3697 Phone #: ###-#### >> Inspection requested via web by Troy Cobb Inspection cancelled from web by: Troy Cobb
ELE19-04182 Final6/14/20206/15/20206/15/2020 10:43:54 AMAPASS
Call with any questions thanks! Phone #: ###-#### Inspection requested via web by Trevor Soesbe Final ok
ELE19-04799 Electrical Rough-In6/12/20206/15/20206/15/2020 9:59:34 AMAPASS
Area A level 4 elevated concrete deck rough in Phone #: ###-#### Inspection requested via web by Jason Parke Discussed when areas can be wired and wiring methods permitted. 334.10- NM cable ok in type 3, 4, and 5 construction. (Wood). Wiring methods rated for damp locations can be installed any time, wiring methods rated for dry locations are install at own risk. If exposed to moisture must be replaced. Area noted pour rough in ok cover.
ELE20-01892 Electrical Rough-In6/11/20206/15/20206/15/2020 9:30:32 AMAFAIL
Phone #: ###-#### Inspection requested via web by Kerri Hamilton South 1/2 of TI and insulate same ceiling ok but no city approved set of prints on site. Informedwork space shall be provided for HVAC units in ceiling. Soffits built too close. Perimeter soffit shall provide access to junction boxes installed at core and shell build. Recall when prints on site.