ELE04-00738
| ELE-Aging Inspection | 6/16/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | | NR |
|
|
will call in for mon. 6/18/2004 3:55:51 PM
|
ELE03-02304
| ELE-Aging Inspection | 6/16/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | | PASS |
|
|
|
ELE03-02903
| ELE-Aging Inspection | 6/16/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | | NR |
|
|
waiting for id power to finish their end op the job 6/18/2004 3:20:39 PM
|
ELE04-01764
| Temporary Service | 6/15/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | A | PASS |
|
|
###-#### Barbara
T/S U/G Ok 6/16/2004 10:07:57 AM
|
ELE04-01319
| Final | 6/15/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | A | NR |
|
|
Brandon; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
|
ELE04-01671
| Electrical Rough-In | 6/15/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | A | PART |
|
|
###-####. Scheduled by a contractor via Hello! on 6/15/2004 at 2:17:42 PM. Contact: ###-####. 6/16/2004 7:34:05 AM
walls only in 3 classrooms and new science lab on 2nd floor 6/16/2004 9:03:23 AM
|
ELE04-01776
| Permanent Service | 6/15/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | A | NR |
|
|
mike-- ###-#### MUST CALL BEFORE INSP FOR DOG
called contractor he will reschedual 6/16/2004 9:01:16 AM
|
ELE04-01730
| Electrical Rough-In | 6/15/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | A | FAIL |
|
|
Nick; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
110.12 Mechanical Execution of Work.
(C) Integrity of Electrical Equipment and Connections. Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, shall not be damaged or contaminated.
300.10 Electrical Continuity of Metal Raceways and Enclosures.
Metal raceways, cable armor, and other metal enclosures for conductors shall be metallically joined together into a continuous electric conductor and shall be connected to all boxes,
250.119 Identification of Equipment Grounding Conductors.
Unless required elsewhere in this Code, equipment grounding conductors shall be permitted to be bare, covered, or insulated. Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green.
200.6Means of Identifying Grounded Conductors.
(A) Sizes 6 AWG or Smaller.
250.66 Size of Alternating-Current Grounding Electrode Conductor.
The size of the grounding electrode conductor of a grounded or ungrounded ac system shall not be less than given in Table 250.66
310.15 Ampacities for Conductors Rated 0-2000 Volts.
(A) General.
(1) Tables or Engineering Supervision. Ampacities for conductors shall be permitted to be determined by tables or under engineering supervision, as provided in 310.15(B) and (C).
6/16/2004 10:26:36 AM
|
ELE04-01319
| Electrical Rough-In | 6/16/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | A | PASS |
|
|
R/I Ok
|
ELE04-01747
| Temporary Service | 6/14/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | P | PASS |
|
|
###-#### steve
T/S U/g Ok 6/16/2004 1:58:10 PM
|
ELE03-00349
| Final | 6/14/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | P | PASS |
|
|
###-#### tyler Homeowner will be home between 1 pm and 3:30pm
Kitchen and dinning room ok 6/16/2004 2:50:22 PM
|
ELE04-00979
| Final | 6/15/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 6/15/2004 at 7:52:50 PM. Contact: ###-####.
|
ELE04-01784
| Electrical Rough-In | 6/16/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | P | PASS |
|
|
###-#### John
|
ELE04-01785
| Final | 6/16/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | P | NH |
|
|
caqlled left messaqge 6/16/2004 3:25:10 PM
|
ELE04-01313
| Conference | 6/16/2004 | 6/16/2004 | 6/16/2004 12:00:00 AM | P | PART |
|
|
1:30 pm Craig; Phone #: ###-#### please call first for access Internet Inspection Request from: Aimee Hughes 6/16/2004 10:35:18 AM
talked about sewage ejection pump 6/16/2004 2:44:18 PM
|