Inspections for the day of: Friday, June 16, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02013 Final6/16/20066/16/20066/16/2006 3:53:38 PMPPASS
dennis; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ok card signed
ELE06-02228 Permanent Service6/16/20066/16/20066/16/2006 3:20:18 PMPFAIL
Please call my cell if you have any questions. Thanks, Randy; Phone #: ###-#### Internet Inspection Request from: Randy Fletcher called needs #4 GEC to water, no violations retained address both subpanels , range dryer feeds, remove sprinkler and flex fittings from emt, label panels, seal KOs job not ready
ELE06-02207 Rough-In Permanent Service6/16/20066/16/20066/16/2006 2:44:28 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. not made fee due, called 300.4(A)(1)&(D) nail plates and 11/4" from inside and outside edges
ELE06-02226 Electrical Rough-In6/16/20066/16/20066/16/2006 2:01:02 PMPNH
oga; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles notice posted called
ELE06-00935 Final6/16/20066/16/20066/16/2006 1:21:25 PMPNR
kyle ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley talked with electricians on site not ready
ELE06-02142 Rough-In Permanent Service6/16/20066/16/20066/16/2006 1:05:50 PMPPASS
###-####. r/i p/s u/g new ok
ELE06-02131 Electrical Rough-In6/13/20066/16/20066/16/2006 12:25:14 PMPPART
r/i u/g uf and concrete cover for electrode ok only
ELE06-02131 Permanent Service6/16/20066/16/20066/16/2006 12:24:00 PMPPASS
Service change 200 amp to 400 amp. Id Power disconnecting at 9:00 am. Inspection required for reconnect.; Phone #: ###-#### Internet Inspection Request from: Julie Schroder p/s u/g rec. ok
ELE05-04666 Final6/16/20066/16/20066/16/2006 11:55:51 AMPPASS
Scheduled by a contractor via Hello! on 6/16/2006 at 8:22:10 AM. Contact: ###-####. final ok UL ok for x-ray unit
ELE06-01542 Electrical Rough-In6/15/20066/16/20066/16/2006 10:56:14 AMAPASS
Scheduled by a contractor via Hello! on 6/15/2006 at 4:19:01 PM. Contact: ###-####. r/i walls and ceilings ok new rest rms also bond water system(new) to building p/s
ELE06-02227 Final6/15/20066/16/20066/16/2006 10:19:32 AMAFAIL
may enter through gate on east side of house. Curtis; Phone #: ###-#### Internet Inspection Request from: Curtis Dunham corr. called needs outlet for spa, bonding for spa, calc p/s for size, spa not listed, use manufactures breakers only
ELE06-01488 Final6/15/20066/16/20066/16/2006 9:42:20 AMAFAIL
Work performed by Joe Schneehagen; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz 314.20 needs box extensions kit & micro wave outlets, 210.52 outlet above baseboard heater, 410.8 (BCD) needs approved fixture closet, 406.3 grded outlets on non grd circuit replace, gfic protect and labels you choose corr. called
ELE06-01807 Electrical Rough-In6/16/20066/16/20066/16/2006 8:51:05 AMAFAIL
A.M. rough-in inspection for the ceiling in the customer areas. Thanks.; Phone #: ###-#### Internet Inspection Request from: Steve Syltie corr. not made
ELE06-02219 Temporary Service6/15/20066/16/20066/16/2006 8:03:36 AMAPASS
Scheduled by a contractor via Hello! on 6/15/2006 at 2:54:11 PM. Contact: ###-####. t/s u/g new ok