ELE08-00568
| ELE-Aging Inspection | 6/16/2008 | 6/16/2008 | 6/23/2008 7:36:43 AM | | DONE |
|
|
called to have installer contact us for inspection, no esc this project
|
ELE08-01549
| Final | 6/16/2008 | 6/16/2008 | 6/16/2008 3:58:42 PM | P | PASS |
|
|
Final inspection. Kelly Tarter ###-#### Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson corrections made, ok to final, no esc
|
ELE08-01606
| Electrical Rough-In | 6/16/2008 | 6/16/2008 | 6/16/2008 3:10:56 PM | P | PASS |
|
|
wall inspection Phone #: ###-#### Internet Inspection Request from: Celinda Winters walls only ok to cover, no esc
|
ELE06-04513
| ELE-Aging Inspection | 6/16/2008 | 6/16/2008 | 6/16/2008 2:07:59 PM | | DONE |
|
|
see final
|
ELE06-04513
| Final | 6/16/2008 | 6/16/2008 | 6/16/2008 2:07:37 PM | P | PASS |
|
|
corrections made, ok to final
|
ELE08-01605
| Permanent Service | 6/16/2008 | 6/16/2008 | 6/16/2008 1:30:22 PM | P | PASS |
|
|
p/s o/h rec ok, no esc
|
ELE08-00376
| Permanent Service | 6/16/2008 | 6/16/2008 | 6/16/2008 1:29:12 PM | P | PASS |
|
|
Tom Phone #: ###-#### p/s o/h n ok, no esc
|
ELE08-01605
| Final | 6/16/2008 | 6/16/2008 | 6/16/2008 1:11:41 PM | P | PASS |
|
|
Mitch- service mass Phone #: ###-#### p/s o/h rec ok, no esc
|
ELE08-00402
| Final | 6/16/2008 | 6/16/2008 | 6/16/2008 12:43:05 PM | P | FAIL |
|
|
Dave Phone #: ###-#### called contractor, left correction notice,NEC 408.4 shall provide circuit directory that is clear, concise and explanatory, 422.31(B) shall provide water heater disconnect, 406.4(D) receptacle faces shall be flush with or project from faceplate, BCC address shall be posted on dwelling and services, no esc
|
ELE06-01751
| Final | 6/16/2008 | 6/16/2008 | 6/16/2008 9:54:02 AM | A | PASS |
|
|
ok to final
|
ELE06-01750
| Final | 6/16/2008 | 6/16/2008 | 6/16/2008 9:50:49 AM | A | PASS |
|
|
ok to final
|
ELE07-01585
| Final | 6/16/2008 | 6/16/2008 | 6/16/2008 9:45:00 AM | A | PASS |
|
|
ok to final
|
ELE06-04225
| Final | 6/16/2008 | 6/16/2008 | 6/16/2008 9:13:54 AM | A | PASS |
|
|
ok to final, no esc
|
ELE07-03975
| Final | 6/13/2008 | 6/16/2008 | 6/16/2008 9:11:07 AM | A | PART |
|
|
joe - ###-####- on east and west additions - not being modified, corrections made, ok to final, signed temporary occupancy card copy, check outside receptacles
|
ELE08-01598
| Final | 6/13/2008 | 6/16/2008 | 6/16/2008 8:32:48 AM | A | CANC |
|
|
rocky Phone #: ###-#### Note: please call 1/2 hr prior to inspection, passed power connect, need to inspect for final, no esc
|
ELE08-01598
| Permanent Service | 6/13/2008 | 6/16/2008 | 6/16/2008 8:25:00 AM | A | PASS |
|
|
rocky Phone #: ###-#### p/s o/h n ok, no esc
|