Inspections for the day of: Thursday, June 16, 2011.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01135 Electrical Rough-In6/16/20116/16/20116/16/2011 2:23:41 PMPPASS
Need the walls approved for cover only Phone #: ###-#### >> Inspection requested via web by Zane Robertson rough-in ok cover walls only
ELE11-00305 Conference6/16/20116/16/20116/16/2011 1:43:17 PMPDONE
panel board
ELE10-01747 ELE-Aging Inspection6/16/20116/16/20116/16/2011 1:01:29 PM DONE
still under construction, will call for rough-in inspection next week
ELE11-01037 Final6/16/20116/16/20116/16/2011 12:45:07 PMPPASS
Lock box code is 4910 Phone #: ###-#### >> Inspection requested via web by Dan Rohl final ok
ELE11-01272 Temporary Service6/16/20116/16/20116/16/2011 12:29:29 PMPPASS
Pole will be outback of the house. Thank you. Chris is contact. Phone #: ###-#### >> Inspection requested via web by Chris Chesnut t/s o/h ok
ELE11-01214 Electrical Rough-In6/15/20116/16/20116/16/2011 12:20:18 PMAPASS
rough in for outlets and switch in new wall. Could you please come around 11am-noon. couple of hours work left in morning, should be ready for rough in by approx 11am. Please call first. Thank you. Phone #: ###-#### >> Inspection requested via web by Tim Dunlop rough-in ok cover walls
ELE11-01257 Final6/16/20116/16/20116/16/2011 10:10:18 AMAPASS
call Joe at ###-#### for access Phone #: ###-#### >> Inspection requested via web by PAT MILLER final ok
ELE11-00640 Final6/16/20116/16/20116/16/2011 9:54:15 AMAPASS
Don Phone #: ###-#### final ok
ELE11-00527 Electrical Rough-In6/16/20116/16/20116/16/2011 9:40:40 AMAPASS
Can you please call me so that I can explain to you what you are looking at.
Thank you, Mark Phone #: ###-#### >> Inspection requested via web by Mark Hennequin rough-in ok cover trenches
ELE11-01270 Electrical Rough-In6/16/20116/16/20116/16/2011 9:26:06 AMAPASS
This is apt 3...an electrician will be on site today if there are questions. Phone #: ###-#### >> Inspection requested via web by Paula Gratiot rough-in ok apartment remodel
ELE11-00378 Final6/14/20116/16/20116/16/2011 9:03:38 AMAFAIL
kevin or ###-#### Jason Phone #: ###-#### NEC 210.4 Each multiwire branch circuit shall be provided with a means that will simultaneously disconnect all ungrounded conductors at the point where the branch circuit originates.
ELE11-01087 Rough-In Permanent Service6/16/20116/16/20116/16/2011 8:38:10 AMAPASS
rough-in p/s u/g n ok
ELE11-01087 Electrical Rough-In6/15/20116/16/20116/16/2011 8:34:45 AMAPASS
mucho Phone #: ###-#### rough-in ok
ELE11-00652 Electrical Rough-In6/15/20116/16/20116/15/2011 12:36:56 PMACANC
Trench inspection please-Michael Phone #: ###-#### rough-in ok cover trench