ELE13-01058
| Final | 6/15/2015 | 6/16/2015 | 6/16/2015 3:51:23 PM | P | PASS |
|
|
final on lighting retrofit exterior on building lights Phone #: ###-#### Inspection requested via web by Tim Dunlop Final ok
|
ELE15-01783
| Final | 6/15/2015 | 6/16/2015 | 6/16/2015 3:37:54 PM | P | PASS |
|
|
Call customer for access Stephanie ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Final ok
|
ELE15-01783
| Electrical Rough-In | 6/16/2015 | 6/16/2015 | 6/16/2015 3:37:39 PM | P | PASS |
|
|
Call customer for access Stephanie ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Rough in ok
|
ELE15-01782
| Final | 6/15/2015 | 6/16/2015 | 6/16/2015 3:30:39 PM | P | PASS |
|
|
Call customer for access Abel Florez ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Final ok
|
ELE15-01782
| Electrical Rough-In | 6/16/2015 | 6/16/2015 | 6/16/2015 3:30:08 PM | P | PASS |
|
|
Call customer for access Abel Florez ###-#### Phone #: ###-#### Inspection requested via web by jamie berg AC rough in ok
|
ELE15-01798
| Final | 6/16/2015 | 6/16/2015 | 6/16/2015 3:19:41 PM | P | PASS |
|
|
wire ac Phone #: ###-#### Inspection requested via web by PAT MILLER Final ok
|
ELE15-01798
| Electrical Rough-In | 6/16/2015 | 6/16/2015 | 6/16/2015 3:18:46 PM | P | PASS |
|
|
wire ac Phone #: ###-#### Inspection requested via web by PAT MILLER Rough in ok
|
ELE15-01656
| Electrical Rough-In | 6/16/2015 | 6/16/2015 | 6/16/2015 2:57:16 PM | P | PASS |
|
|
Phone #: ###-#### Corrections made rough in ok cover
|
ELE15-00915
| Final | 6/16/2015 | 6/16/2015 | 6/16/2015 2:36:01 PM | P | FAIL |
|
|
Garage code is 0500 Phone #: ###-#### Inspection requested via web by TOM BICANDI 110.3- Master bath vanity receptacle not working. 210.12- Up bed outlet shall have AFCI protection. 410.16- Luminaire under stair shall clear shelf by min of 12"
|
ELE15-01787
| Final | 6/15/2015 | 6/16/2015 | 6/16/2015 1:45:53 PM | P | PASS |
|
|
We Went Out To Repair A Tripping Main Breaker And Found The bussing Was Burned From An Unbalanced Load. The Service Is Beyond repair And We Are Changing The Service. Firs Ting This morning. Please Call Me When You Are Headed Thais Way Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett Final ok
|
ELE15-01787
| Permanent Service | 6/16/2015 | 6/16/2015 | 6/16/2015 1:44:47 PM | P | PASS |
|
|
We Went Out To Repair A Tripping Main Breaker And Found The bussing Was Burned From An Unbalanced Load. The Service Is Beyond repair And We Are Changing The Service. Firs Ting This morning. Please Call Me When You Are Headed Thais Way Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett p/s o/h rec ok
|
ELE15-01795
| Rough-In Permanent Service | 6/16/2015 | 6/16/2015 | 6/16/2015 1:24:51 PM | P | FAIL |
|
|
Dan Phone #: ###-#### Inspection requested via web by Dan Hobdey 300.4- NM calbe shall not be ran where it may be subject to physical damage. master bed firewall on clips. 334.30- NM cable shall be secured within 12" of smoke in masteer bed. 334.80- Where 2 or more NM cables are ran through bored holes without maintaining spacing derating calculations shall apply. BCC- Firewall shall be clear for fire barrier. Wiring shall be relocated from behind studs in firewalls in master bed and garage.
|
ELE15-01794
| Rough-In Permanent Service | 6/16/2015 | 6/16/2015 | 6/16/2015 1:14:10 PM | P | FAIL |
|
|
Dan Phone #: ###-#### Inspection requested via web by Dan Hobdey 300.4- NM cable shall not be installed where it may be subject to physical damage. 334.30- MN cable shall be supported every 4 1/2' minimum. Fr. bed, furnace wire. 334.80- Where 2 or more NM cables ran through bored holes without maintaining spacing derating calculations shall apply. BCC- Firewalls shall be clear for fire barrier. Wiring shall be relocated from behind studs in firewalls in master bed and garage.
|
ELE13-01023
| ELE-Aging Inspection | 6/16/2015 | 6/16/2015 | 6/16/2015 11:15:20 AM | | CANC |
|
|
too busy
|
ELE13-00354
| ELE-Aging Inspection | 6/16/2015 | 6/16/2015 | 6/16/2015 11:10:43 AM | | DONE |
|
|
Waiting on owner
|
ELE12-02995
| ELE-Aging Inspection | 6/16/2015 | 6/16/2015 | 6/16/2015 11:09:44 AM | | DONE |
|
|
Waiting on owner
|
ELE12-02434
| ELE-Aging Inspection | 6/16/2015 | 6/16/2015 | 6/16/2015 11:05:43 AM | | DONE |
|
|
Waiting on contractor
|
ELE15-01770
| Electrical Rough-In | 6/16/2015 | 6/16/2015 | 6/16/2015 10:55:56 AM | A | PASS |
|
|
Call Daniel if you have any questions. Thank you ###-#### Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover
|
ELE15-01765
| Final | 6/15/2015 | 6/16/2015 | 6/16/2015 10:13:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Thomas wilson Final ok
|
ELE15-01545
| Rough-In Permanent Service | 6/16/2015 | 6/16/2015 | 6/16/2015 9:58:24 AM | A | PASS |
|
|
Gary is the onsite contact at ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover p/s u/g n ok
|
ELE15-01551
| Conference | 6/15/2015 | 6/16/2015 | 6/16/2015 9:29:56 AM | A | DONE |
|
|
John Phone #: ###-#### discussed installation of a hot tub on back patio. Bonding ofmetal gutter with in 5 ' of waters edge, wire size, wiring path, disconnect location
|
ELE15-01747
| Rough-In Permanent Service | 6/15/2015 | 6/16/2015 | 6/16/2015 8:57:25 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE15-01776
| Electrical Rough-In | 6/15/2015 | 6/16/2015 | 6/16/2015 8:26:08 AM | A | PASS |
|
|
Underground Phone #: ###-#### Inspection requested via web by Eric Brown Hot tub going north side of existing pool check over head clearance of power lines, Under ground rough in ok cover
|