PLM15-00158
| PLM-Aging Inspection | 6/16/2015 | 6/16/2015 | 6/16/2015 4:58:14 PM | | PART |
|
|
no call
|
PLM15-01959
| Water Heater Final | 6/15/2015 | 6/16/2015 | 6/16/2015 4:57:26 PM | A | FAIL |
|
|
Call prior ###-#### Phone #: ###-#### Inspection requested via web by curtis rowe====Need to supply carbon monoxide detectors per R315.2
|
PLM15-01956
| Water Softner Final | 6/15/2015 | 6/16/2015 | 6/16/2015 4:54:11 PM | P | FAIL |
|
|
please call customer when on the way ###-#### thanks Phone #: ###-#### Inspection requested via web by brandon winkler=====Need to provide carbon monoxide detector at bedrooms other than master per R315.2 code, need screws in b vent at swivel connector.
|
PLM14-03117
| Plumbing Rough-in | 6/16/2015 | 6/16/2015 | 6/16/2015 4:11:06 PM | P | PASS |
|
|
Office only mait Phone #: ###-#### Inspection requested via web by j mait downer jr
|
PLM15-01913
| Final | 6/16/2015 | 6/16/2015 | 6/16/2015 3:16:16 PM | P | PASS |
|
|
please call Bob with any questions Suite A Phone #: ###-#### Inspection requested via web by Nicholas Paige
|
PLM15-01837
| Water and/or Sewer | 6/16/2015 | 6/16/2015 | 6/16/2015 3:11:02 PM | P | PASS |
|
|
Water line
|
PLM15-01837
| DOC - Permit Finaled | 6/16/2015 | 6/16/2015 | 6/16/2015 3:10:41 PM | P | PASS |
|
|
|
PLM15-01976
| Plumbing Rough-in | 6/16/2015 | 6/16/2015 | 6/16/2015 2:45:08 PM | P | FAIL |
|
|
JOB # 18033. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes====Leak in ceiling of lower left from lav above, strap water lines in wall at water heaters all units. retest and re inspect
|
PLM15-01371
| Groundwork | 6/15/2015 | 6/16/2015 | 6/16/2015 2:23:42 PM | P | PART |
|
|
JOB CONTACT - DAVID ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER====Main water stub in ok
|
PLM15-01909
| Plumbing Rough-in | 6/16/2015 | 6/16/2015 | 6/16/2015 2:01:43 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Raul Castanon====Need nail plates, water lines were not installed at time of GW inspection.
|
PLM15-00698
| Final | 6/15/2015 | 6/16/2015 | 6/16/2015 1:39:07 PM | P | PASS |
|
|
call for access Phone #: ###-#### Inspection requested via web by Josh Kelley
|
PLM15-01920
| Groundwork | 6/16/2015 | 6/16/2015 | 6/16/2015 1:02:42 PM | P | PASS |
|
|
Any questions call Rick. Thanks Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM15-01852
| Groundwork | 6/16/2015 | 6/16/2015 | 6/16/2015 11:44:41 AM | A | PASS |
|
|
As late as possible Phone #: 3533696 >> Inspection requested via mobile web by Stephen
|
PLM15-01948
| Water and/or Sewer | 6/15/2015 | 6/16/2015 | 6/16/2015 11:43:22 AM | A | PART |
|
|
Water and Sewer Line Inspection Phone #: ###-#### Inspection requested via web by Vicki Tallent===Sewer ok to bury, water not holding test, call for inspection when complete
|
PLM15-00748
| Final | 6/15/2015 | 6/16/2015 | 6/16/2015 10:54:02 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Salamon
|
PLM15-01938
| Water and/or Sewer | 6/15/2015 | 6/16/2015 | 6/16/2015 10:26:19 AM | A | PASS |
|
|
Test will be on by 9am. thank you. Phone #: ###-#### Inspection requested via web by Bob Bivin
|
PLM15-01947
| Water and/or Sewer | 6/15/2015 | 6/16/2015 | 6/16/2015 9:53:57 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Kirk Johns====SH valve ok,
|
PLM15-01837
| Water and/or Sewer | 6/15/2015 | 6/16/2015 | 6/16/2015 9:36:45 AM | A | NR |
|
|
Water Line; Jeff Phone #: ###-####
|
PLM15-01957
| Water and/or Sewer | 6/15/2015 | 6/16/2015 | 6/16/2015 9:24:29 AM | P | CANC |
|
|
Please Contact Luis Ornelas @ ###-#### for any questions. Phone #: ###-#### >> Inspection requested via web by Accounts Payable Inspection cancelled from web by: Accounts Payable
|
PLM15-01939
| Water and/or Sewer | 6/16/2015 | 6/16/2015 | 6/16/2015 9:18:40 AM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Clayne Baker=====ok to bury, DCVA needs certified to close permit, call for inspection when completed
|
PLM15-01928
| Sprinkler (Final) | 6/15/2015 | 6/16/2015 | 6/16/2015 9:04:48 AM | A | FAIL |
|
|
Marco Phone #: ###-####====Need union within 12" of device
|