ELE12-00588
| ELE-Aging Inspection | 6/16/2016 | 6/16/2016 | 6/17/2016 7:29:55 AM | | CANC |
|
|
too busy
|
ELE12-02548
| ELE-Aging Inspection | 6/16/2016 | 6/16/2016 | 6/17/2016 7:29:40 AM | | CANC |
|
|
too busy
|
ELE16-01602
| Final | 6/16/2016 | 6/16/2016 | 6/16/2016 3:24:35 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Don Conley correction fixed final ok
|
ELE16-01604
| Final | 6/16/2016 | 6/16/2016 | 6/16/2016 2:56:12 PM | P | PASS |
|
|
fixed to comply
110.26 151v-600v shall maintain 48" of working clearences Phone #: ###-#### Inspection requested via web by Tim Dunlop correction fixed final ok
|
ELE16-01677
| Final | 6/16/2016 | 6/16/2016 | 6/16/2016 2:48:18 PM | P | PASS |
|
|
Phone #: 2088694676 >> Inspection requested via mobile web by Barry Spencer Solar array final ok
|
ELE16-01898
| Conference | 6/16/2016 | 6/16/2016 | 6/16/2016 2:35:45 PM | P | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Scott Seward discussed electrical requirements for detached garage/in law quarters. new service on garage will eventually feed house. owner will pull new building permit for job as well
|
ELE16-01478
| Final | 6/16/2016 | 6/16/2016 | 6/16/2016 1:24:09 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|
ELE16-01867
| Rough-In Permanent Service | 6/16/2016 | 6/16/2016 | 6/16/2016 12:39:20 PM | P | PASS |
|
|
roughin for ceilings and service inspect Phone #: ###-#### Inspection requested via web by Tracy Robertson Hard lid cielings only ok cover p/s u/g nok i meter required
|
ELE16-01761
| Final | 6/15/2016 | 6/16/2016 | 6/16/2016 12:39:13 PM | P | PASS |
|
|
Thanks,
Al Curl Phone #: ###-#### Inspection requested via web by Scott Campbell Final ok
|
ELE16-01739
| Conference | 6/15/2016 | 6/16/2016 | 6/16/2016 11:07:29 AM | A | DONE |
|
|
would like call haead; Shon Phone #: ###-#### Discussed code requirements for addition and pool equipment.
|
ELE16-01897
| Conference | 6/15/2016 | 6/16/2016 | 6/16/2016 10:11:50 AM | A | DONE |
|
|
Please call 30 minutes in advance for access Phone #: ###-#### Inspection requested via web by Kerri Hamilton Discussed service change requirments for duplex. disc will be grouped and range and dryer will be re fed to 4 wire
|
ELE16-01417
| Final | 6/15/2016 | 6/16/2016 | 6/16/2016 9:46:33 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wake final for service change ok
|
ELE16-01418
| Final | 6/15/2016 | 6/16/2016 | 6/16/2016 9:45:59 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wake 680.26(6) bonding of pumps shall not be smaller then #8 680.22 permanetly installed pools shall at least one receptacle within 20' and not closer then 6'
|
ESC15-01435
| Site Final | 6/16/2016 | 6/16/2016 | 6/16/2016 9:17:32 AM | P | PASS |
|
|
site final ok
|
ELE16-01891
| Permanent Service | 6/16/2016 | 6/16/2016 | 6/16/2016 9:07:50 AM | P | PASS |
|
|
p/s u/g rec ok
|
ELE16-01891
| Final | 6/15/2016 | 6/16/2016 | 6/16/2016 9:05:35 AM | A | PASS |
|
|
service off longer than 1 year; call for access info, Sergio Phone #: ###-#### p/s u/g rec ok
|
ELE16-01820
| Rough-In Permanent Service | 6/15/2016 | 6/16/2016 | 6/16/2016 8:38:25 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn rough-in ok cover p/s u/g n ok
|