ELE17-01891
| Final | 6/16/2017 | 6/16/2017 | 6/16/2017 2:39:52 PM | P | PASS |
|
|
If you have any questions please call Jeremiah at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell Ok final
|
ELE17-01878
| Permanent Service | 6/16/2017 | 6/16/2017 | 6/16/2017 2:36:13 PM | P | PASS |
|
|
Roger Phone #: ###-#### p/s u/g rec ok. Customer needed a new 200a meter base. Existing wires from IDP a little short.
|
ELE17-01895
| Conference | 6/16/2017 | 6/16/2017 | 6/16/2017 12:02:30 PM | P | DONE |
|
|
Alan Phone #: ###-#### Discussed moving washer outlet up so GFI is accessable, and changing out box to allow for box fill. All grounds in boxes need tied together with 1 pigtail to ground switches and outlets. All metal boxes need ground screws.
|
ELE17-01853
| Final | 6/16/2017 | 6/16/2017 | 6/16/2017 11:42:04 AM | P | PASS |
|
|
Robert Phone #: ###-#### ok final. Breakered at 30a which is max fuse
|
ELE17-01729
| Electrical Rough-In | 6/15/2017 | 6/16/2017 | 6/16/2017 11:23:23 AM | P | PASS |
|
|
David Forbes ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Ok cover bar area up front and back 2 baths and storage area.
|
ELE17-01891
| Permanent Service | 6/16/2017 | 6/16/2017 | 6/16/2017 11:07:07 AM | P | PASS |
|
|
If you have any questions please call Jeremiah at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell p/s o/h rec ok. Homeowners wanted to label panel themselves. Notified contractor and mentioned that they needed to label panel due to possibility on incorrect labeling, which could be a liabilty in the future.
|
ELE17-01860
| Electrical Rough-In | 6/16/2017 | 6/16/2017 | 6/16/2017 10:00:16 AM | A | PASS |
|
|
Call Dylan ###-#### half hour prior for access. Thank you Phone #: ###-#### Inspection requested via web by daniel bibikov Ok cover N wall. Existing wall was pushed back a couple of feet.
|
ELE17-00503
| Final | 6/14/2017 | 6/16/2017 | 6/16/2017 9:39:51 AM | A | PASS |
|
|
1919 CODE Phone #: ###-#### Inspection requested via web by Neal Rumsey Ok final
|
ELE17-01234
| Final | 6/15/2017 | 6/16/2017 | 6/16/2017 9:06:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Ok final
|
ELE17-01882
| Electrical Rough-In | 6/15/2017 | 6/16/2017 | 6/16/2017 8:49:28 AM | A | CANC |
|
|
Pool bond for apron and motorized cover Phone #: ###-#### Inspection requested via web by TOM BICANDI Contractor wants to change to a Conference to discuss pool equipotential bonding
|
ELE17-01878
| Conference | 6/15/2017 | 6/16/2017 | 6/16/2017 8:07:58 AM | A | DONE |
|
|
Roger-customer has Id Power coming out about 9 Phone #: ###-#### Talked to homeowner on phone. He is changing 100a to 200a panel. Meter is rated for 200a. He is changing GEC to #4 to ufer.
|