Inspections for the day of: Friday, June 16, 2017.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-02132 Final6/15/20176/16/20176/16/2017 4:29:00 PMPPASS
Please call Janice Denney at ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM17-01537 Final6/16/20176/16/20176/16/2017 4:11:37 PMPPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
PLM17-00485 Final6/16/20176/16/20176/16/2017 4:03:30 PMPFAIL
Phone #: ###-#### Inspection requested via web by Andrew Wilde.
Provide an air-gap on the relief valve drain.
Install a tempering valve on the public restroom lavatory sink.
PLM17-01861 Final6/16/20176/16/20176/16/2017 3:22:26 PMPPASS
No sprinkler system present - Nate Phone #: ###-####
PLM17-01939 Sprinkler (Final)6/15/20176/16/20176/16/2017 3:08:48 PMAPASS
Toni Phone #: ###-####
PLM17-00572 Final6/16/20176/16/20176/16/2017 3:00:50 PMPPASS
READY NOW - if questions call Mark ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
PLM17-01331 Final6/16/20176/16/20176/16/2017 2:49:55 PMPPASS
PLM17-02202 Final6/15/20176/16/20176/16/2017 12:08:00 PMAFAIL
Call Mike with an ETA ; for ACCESS ###-####. Any other questions call Tim @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann. T&P drain line must be full size pipe. ISPC 608.5
PLM17-02173 Sprinkler (Final)6/15/20176/16/20176/16/2017 11:28:03 AMAPASS
Phone #: ###-#### Inspection requested via web by Todd Linde
PLM17-02178 Water Heater Final6/14/20176/16/20176/16/2017 11:19:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Chris Field
PLM17-02179 Water Heater Final6/14/20176/16/20176/16/2017 11:03:48 AMAFAIL
PLEASE CALL JEREMY WHEN YOU ARE ON YOUR WAY Phone #: ###-#### Inspection requested via web by JEREMY LINK. Flex connector cannot be used on the t&p. Hard pipe and draill a 1/16" hole in the low point.
PLM17-02209 Plumbing Rough-in6/15/20176/16/20176/16/2017 10:20:49 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Branden Steers Inspection cancelled from web by: Branden Steers
PLM17-00785 Final6/15/20176/16/20176/16/2017 10:13:57 AMAFAIL
JOB # 50626 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes.
The water heater must have 2" clearance all the way around the pan per the manufacturers installation instructions.
PLM17-02206 Water and/or Sewer6/15/20176/16/20176/16/2017 9:27:30 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM17-02206 Final6/16/20176/16/20176/16/2017 9:27:14 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM17-02204 Water and/or Sewer6/15/20176/16/20176/16/2017 9:21:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM17-02204 Final6/16/20176/16/20176/16/2017 9:21:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM17-02205 Water and/or Sewer6/15/20176/16/20176/16/2017 9:19:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM17-02205 Final6/16/20176/16/20176/16/2017 9:18:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM17-02205 Final6/16/20176/16/20176/16/2017 9:17:00 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM16-04200 Plumbing Rough-in6/15/20176/16/20176/16/2017 8:44:30 AMAPASS
Phone #: ###-#### Inspection requested via web by Rob Bristol
PLM17-02033 Water and/or Sewer6/14/20176/16/20176/15/2017 2:01:51 PMAPART
Please call job Foreman before arriving. Foreman is Bo ###-####. PM is Mike Jackosn ###-####. Phone #: ###-#### Inspection requested via web by judy patton. Sewer and water ok to cover. Water line needs final after meter connection