PLM10-01390
| Plumbing Rough-in | 6/17/2010 | 6/18/2010 | 6/18/2010 10:58:59 AM | A | PASS |
|
|
Doug ###-#### ri gw ok
|
PLM10-00224
| Final | 6/17/2010 | 6/18/2010 | 6/18/2010 10:25:51 AM | A | FAIL |
|
|
damion Phone #: ###-#### - please call for access pan drain required under the water heater piped to exterior. water heater T&P drain needs flex connector removed and piped to exterior. permit required for the sprinkler system backflow preventer. expose connection to main, test PVB, call for inspection
|
PLM10-00606
| Water and/or Sewer | 6/17/2010 | 6/18/2010 | 6/18/2010 9:59:46 AM | A | FAIL |
|
|
Inspection requested from web by: ron pierce needs combustion air, t&p ran to exterior, pan drain completed. black fittings and nipples changed out to galvanized. called master rooter, looks like an older water heater???
|
PLM09-00562
| Sprinkler (Final) | 5/28/2010 | 6/18/2010 | 6/18/2010 9:24:13 AM | A | PASS |
|
|
check for inspections looks like corrections were made
|
PLM10-01326
| Plumbing Rough-in | 6/17/2010 | 6/18/2010 | 6/18/2010 9:17:19 AM | A | PASS |
|
|
replaced waste pipe and ran vent - no trim to do Inspection requested from web by: fritz ramisch Phone #: ###-####
|
PLM10-01326
| Final | 6/18/2010 | 6/18/2010 | 6/18/2010 9:17:09 AM | A | PASS |
|
|
replaced waste pipe and ran vent - no trim to do Inspection requested from web by: fritz ramisch Phone #: ###-####
|