Inspections for the day of: Thursday, June 18, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02548 ELE-Aging Inspection6/18/20156/18/20156/19/2015 7:43:09 AM CANC
Too busy
ELE15-00915 Final6/18/20156/18/20156/18/2015 2:13:20 PMPFAIL
Phone #: ###-#### Inspection requested via web by TOM BICANDI Previous corrections complete.
110.12- Up bed circuit shall be free of faults. Breaker will not hold.
ELE15-01834 Final6/18/20156/18/20156/18/2015 1:23:04 PMPPASS
Contact home owner for access Bob Ancin ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Mini split system final ok
ELE14-00055 Final6/18/20156/18/20156/18/2015 12:35:36 PMPPASS
code 2234 Phone #: ###-#### Inspection requested via web by Shaun Kirkman Final ok
ELE15-01512 Electrical Rough-In6/18/20156/18/20156/18/2015 12:00:20 PMPFAIL
Overhead, above ceiling - Scott Phone #: ###-#### 4-05-32- Code violation not to be retained.
300.11- Ceiling grid shall not support low volt wiring. Existing low volt wiring shall be removed or supported indepandant of grid.
ELE15-01821 Electrical Rough-In6/17/20156/18/20156/18/2015 11:15:18 AMAFAIL
Phone #: ###-#### Inspection request via web by Steve Craig 300.4- NM cable shall be protected from physical damage where ran thru notched or bored holes that do not maintain 1 1/4" from framing surface.
725.136- Low volt wiring for chime shall not accupy same box as power wiring.
Complete equipment grounding for sub panel.
Room between apartment and house not wired.
#2 Ser ran to sub panel check overcurrent.
Addition to 2109
ELE15-01826 Final6/17/20156/18/20156/18/2015 10:39:40 AMAPASS
Phone #: ###-#### Inspection requested via web by steve ragan Final ok
ELE15-01826 Permanent Service6/18/20156/18/20156/18/2015 10:35:05 AMPPASS
Phone #: ###-#### Inspection requested via web by steve ragan p/s o/h rec ok
ELE15-01824 Final6/17/20156/18/20156/18/2015 10:12:28 AMACANC
We are requesting a wall rough-in inspection for tomorrow 6/18/15 in the AM. Our onsite contact is Rich @ ###-####. Thank you Phone #: ###-#### Inspection requested via web by Clint Tate Needed rough in inspection
ELE15-01824 Electrical Rough-In6/18/20156/18/20156/18/2015 10:08:47 AMPPASS
We are requesting a wall rough-in inspection for tomorrow 6/18/15 in the AM. Our onsite contact is Rich @ ###-####. Thank you Phone #: ###-#### Inspection requested via web by Clint Tate Offices not ready, secure wall rough in ok cover
ELE15-01830 Temporary Service6/18/20156/18/20156/18/2015 9:44:41 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov t/s u/g n ok
ELE15-01829 Temporary Service6/18/20156/18/20156/18/2015 9:34:12 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov t/s u/g n ok
ELE15-01832 Temporary Service6/18/20156/18/20156/18/2015 9:18:17 AMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE15-01831 Temporary Service6/18/20156/18/20156/18/2015 9:11:15 AMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE14-03464 Final6/17/20156/18/20156/18/2015 8:50:14 AMAPASS
Garage code: 4669 Phone #: ###-#### Inspection requested via web by Lynn Solmon Final ok
ELE15-01780 Temporary Service6/17/20156/18/20156/18/2015 8:20:49 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok