ELE06-00934
| ELE-Aging Inspection | 6/19/2006 | 6/19/2006 | 6/19/2006 4:45:38 PM | | DONE |
|
|
see final
|
ELE06-00934
| Final | 6/19/2006 | 6/19/2006 | 6/19/2006 4:44:23 PM | P | PASS |
|
|
looked at signs, ok to final
|
ELE05-03150
| ELE-Aging Inspection | 6/19/2006 | 6/19/2006 | 6/19/2006 4:43:26 PM | | DONE |
|
|
suc
|
ELE06-02250
| Rough-In Permanent Service | 6/19/2006 | 6/19/2006 | 6/19/2006 4:40:01 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas called, left corr notice, nec 314.20 in walls of combustible material, boxes shall be flush with finished surface, 300.4(A)&(D) edge of holes and nm cable shall be 11/4" from edge of framing member,210.52(E) at least 1 outdoor outlet shall be at front of dwelling,BCC all make-up shall be done and boxes mounted
|
ELE06-02249
| Electrical Rough-In | 6/19/2006 | 6/19/2006 | 6/19/2006 4:24:34 PM | P | CANC |
|
|
Rick; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt see rip
|
ELE06-02249
| Rough-In Permanent Service | 6/19/2006 | 6/19/2006 | 6/19/2006 4:24:09 PM | P | PASS |
|
|
Rick; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt called cont, ric ok, p/s u/g n ok
|
ELE06-02246
| Electrical Rough-In | 6/19/2006 | 6/19/2006 | 6/19/2006 3:02:59 PM | P | PASS |
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Darla Downs walls and ceilings ok to cover
|
ELE06-01346
| Electrical Rough-In | 6/16/2006 | 6/19/2006 | 6/19/2006 2:43:24 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: JENNY EMEL ok to cover ceilings
|
ELE06-01078
| Final | 6/19/2006 | 6/19/2006 | 6/19/2006 1:59:42 PM | P | PASS |
|
|
Richard; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok to final
|
ELE06-00191
| Permanent Service | 6/19/2006 | 6/19/2006 | 6/19/2006 1:36:02 PM | P | PASS |
|
|
bruce - might be listed as 2901 on mailbox; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s u/g n ok
|
ELE06-02254
| Electrical Rough-In | 6/19/2006 | 6/19/2006 | 6/19/2006 1:04:30 PM | P | PART |
|
|
pole inspection ###-#### ok to pour ,anop
|
ELE06-02195
| Final | 6/16/2006 | 6/19/2006 | 6/19/2006 11:49:38 AM | A | PASS |
|
|
debbie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
|
ELE06-00391
| Final | 6/16/2006 | 6/19/2006 | 6/19/2006 10:45:07 AM | A | PASS |
|
|
debbie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final, talked to elect, no subpanel
|
ELE05-03533
| ELE-Aging Inspection | 6/19/2006 | 6/19/2006 | 6/19/2006 10:34:00 AM | | DONE |
|
|
nr,suc
|
ELE06-02155
| Electrical Rough-In | 6/19/2006 | 6/19/2006 | 6/19/2006 10:21:47 AM | A | PASS |
|
|
bonding and partial underground is ready to go. autocover,2ea lights. no ladders or rails. thanx joe; Phone #: ###-#### Internet Inspection Request from: joe wheeler pool bond and u/g except west end of pool ok to cover. Need to see equipotential plane grounding later
|
ELE06-02243
| Final | 6/16/2006 | 6/19/2006 | 6/19/2006 10:02:39 AM | A | PASS |
|
|
jesse; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to final
|
ELE06-02225
| Rough-In Permanent Service | 6/19/2006 | 6/19/2006 | 6/19/2006 9:31:32 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 6/19/2006 at 6:43:42 AM. Contact: ###-####. corr made, ric ok, p/s u/g n ok
|
ELE06-02093
| Rough-In Permanent Service | 6/16/2006 | 6/19/2006 | 6/19/2006 9:05:42 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 6/16/2006 at 4:22:35 PM. Contact: ###-####. corr made, ric ok, p/s u/g n ok
|
ELE06-02116
| Electrical Rough-In | 6/16/2006 | 6/19/2006 | 6/19/2006 8:46:36 AM | A | PASS |
|
|
NEED INSPECTION ON UNDERGROUND CONDUIT. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH u/g slab only ok to cover
|
ELE06-02178
| Electrical Rough-In | 6/16/2006 | 6/19/2006 | 6/19/2006 8:24:04 AM | A | PASS |
|
|
this is for an ufer inspection, any questions please call Ed Schallock; Phone #: ###-#### Internet Inspection Request from: Jeff Radford ok to pour gec, talked to contr about addressing
|