Inspections for the day of: Thursday, June 19, 2008.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorForrest France
TitleFIRE INSPECTOR
Phone #794-1981
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD08-00130 FIRE-Final Inspection6/19/20086/19/20086/20/2008 6:38:51 PMPPASS
Fire life safety inspection completed satisfactory, inspection passed.
FIR08-00190 INSP-Final Inspection6/19/20086/19/20086/20/2008 6:38:04 PMPPASS
Fire alarm passed inspection, permit finaled.
BLD08-00740 FIRE-Final Inspection6/19/20086/19/20086/19/2008 3:54:49 PMPPASS
Fire life safety finaled.
BLD08-00739 FIRE-Final Inspection6/19/20086/19/20086/19/2008 3:45:21 PMPPASS
Fire life safety inspection completed satisfactory.
FIR08-00346 INSP-Final Inspection6/19/20086/19/20086/19/2008 3:32:54 PMPPASS
Fire sprinkler final inspection passed, permit finaled.
FIR08-00141 INSP-Final Inspection6/18/20086/19/20086/19/2008 3:31:47 PMAPASS
Fire sprinkler permit finaled.
FIR08-00325 INSP-Final Inspection6/18/20086/19/20086/19/2008 3:31:12 PMAPASS
Fire alarm work passed field testing, permit finaled.
FIR08-00066 INSP-Sprinkler Rough-in6/18/20086/19/20086/19/2008 3:30:23 PMPFAIL
Armover hangers at several locations do not meet requirements of NFPA 13 2007 9.2.3.5.2.1, two heads adjacent to a continuous ceiling obstruction do not meet table 8.6.5.1.2, missing one head per drawings not installed, noted overspaced heads at four locations including a small room and open office areas, heads at an east side OTS room need relocated to avoid obstructions and meet head listing, overhead install is not approved for cover at this time.
BLD08-00075 FIRE-Final Inspection6/19/20086/19/20086/19/2008 1:14:57 PMPPASS
Fire life safety is acceptable, inspection passed.
BLD08-00795 FIRE-Final Inspection6/18/20086/19/20086/19/2008 12:27:35 PMAPASS
Fire life safety okay for final pending the addition of one EM light at the south exit to be installed today per discussion. Also completed preliminary walkthrough for the remainder of area 5A-noted overdue PFE certification, missing sprinkler escutcheons, EM lighitng passed test.
FIR08-00335 INSP-Final Inspection6/19/20086/19/20086/19/2008 12:23:48 PMPPASS
The scope of this fire sprinkler permit work passed inspection, permit finaled.
FIR06-00540 INSP-Final Inspection6/16/20086/19/20086/19/2008 11:49:36 AMADEFR
FIR08-00294 INSP-Final Inspection6/17/20086/19/20086/19/2008 11:45:55 AMAPASS
Fire alarm system additions passed field testing, permit finaled.
FIR08-00141 INSP-Final Inspection6/19/20086/19/20086/19/2008 10:13:16 AMPDEFR
Duplicate inspection request
FIR07-01042 FIR-Aging Inspection6/19/20086/19/20086/19/2008 10:11:57 AM DONE
Work in progress, construction underway.