BLD08-00130
| FIRE-Final Inspection | 6/19/2008 | 6/19/2008 | 6/20/2008 6:38:51 PM | P | PASS |
|
|
Fire life safety inspection completed satisfactory, inspection passed.
|
FIR08-00190
| INSP-Final Inspection | 6/19/2008 | 6/19/2008 | 6/20/2008 6:38:04 PM | P | PASS |
|
|
Fire alarm passed inspection, permit finaled.
|
BLD08-00740
| FIRE-Final Inspection | 6/19/2008 | 6/19/2008 | 6/19/2008 3:54:49 PM | P | PASS |
|
|
Fire life safety finaled.
|
BLD08-00739
| FIRE-Final Inspection | 6/19/2008 | 6/19/2008 | 6/19/2008 3:45:21 PM | P | PASS |
|
|
Fire life safety inspection completed satisfactory.
|
FIR08-00346
| INSP-Final Inspection | 6/19/2008 | 6/19/2008 | 6/19/2008 3:32:54 PM | P | PASS |
|
|
Fire sprinkler final inspection passed, permit finaled.
|
FIR08-00141
| INSP-Final Inspection | 6/18/2008 | 6/19/2008 | 6/19/2008 3:31:47 PM | A | PASS |
|
|
Fire sprinkler permit finaled.
|
FIR08-00325
| INSP-Final Inspection | 6/18/2008 | 6/19/2008 | 6/19/2008 3:31:12 PM | A | PASS |
|
|
Fire alarm work passed field testing, permit finaled.
|
FIR08-00066
| INSP-Sprinkler Rough-in | 6/18/2008 | 6/19/2008 | 6/19/2008 3:30:23 PM | P | FAIL |
|
|
Armover hangers at several locations do not meet requirements of NFPA 13 2007 9.2.3.5.2.1, two heads adjacent to a continuous ceiling obstruction do not meet table 8.6.5.1.2, missing one head per drawings not installed, noted overspaced heads at four locations including a small room and open office areas, heads at an east side OTS room need relocated to avoid obstructions and meet head listing, overhead install is not approved for cover at this time.
|
BLD08-00075
| FIRE-Final Inspection | 6/19/2008 | 6/19/2008 | 6/19/2008 1:14:57 PM | P | PASS |
|
|
Fire life safety is acceptable, inspection passed.
|
BLD08-00795
| FIRE-Final Inspection | 6/18/2008 | 6/19/2008 | 6/19/2008 12:27:35 PM | A | PASS |
|
|
Fire life safety okay for final pending the addition of one EM light at the south exit to be installed today per discussion. Also completed preliminary walkthrough for the remainder of area 5A-noted overdue PFE certification, missing sprinkler escutcheons, EM lighitng passed test.
|
FIR08-00335
| INSP-Final Inspection | 6/19/2008 | 6/19/2008 | 6/19/2008 12:23:48 PM | P | PASS |
|
|
The scope of this fire sprinkler permit work passed inspection, permit finaled.
|
FIR06-00540
| INSP-Final Inspection | 6/16/2008 | 6/19/2008 | 6/19/2008 11:49:36 AM | A | DEFR |
|
|
|
FIR08-00294
| INSP-Final Inspection | 6/17/2008 | 6/19/2008 | 6/19/2008 11:45:55 AM | A | PASS |
|
|
Fire alarm system additions passed field testing, permit finaled.
|
FIR08-00141
| INSP-Final Inspection | 6/19/2008 | 6/19/2008 | 6/19/2008 10:13:16 AM | P | DEFR |
|
|
Duplicate inspection request
|
FIR07-01042
| FIR-Aging Inspection | 6/19/2008 | 6/19/2008 | 6/19/2008 10:11:57 AM | | DONE |
|
|
Work in progress, construction underway.
|