Inspections for the day of: Tuesday, June 19, 2012.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01416 ELE-Aging Inspection6/19/20126/19/20126/21/2012 7:17:01 AM DONE
still under construction
ELE11-01375 ELE-Aging Inspection6/19/20126/19/20126/21/2012 7:16:32 AM DONE
see final
ELE11-02364 Final6/19/20126/19/20126/19/2012 3:23:13 PMPFAIL
Inspect upstairs Rental / Dwelling - 2nd floor. Inspect Cafe - 1st floor. Reinspect service - upgraded wire to 250 MCM & 200A breaker. (Previously bought wrong wire for 200A.) Phone #: ###-#### >> Inspection requested via web by nathan palmer met contractor, he wrote list, shall not have foreign piping in dedicated and work space about panels, shall provide light in mechanical room, tighten receptacle in bath, provide gec id at incoming water pipe, shall demo old wiring, shall mount showroom receptacles, not blank off, shall bond hot and cold water pipes and provide disconnect at upstairs water heater
ELE12-01407 Electrical Rough-In6/19/20126/19/20126/19/2012 2:38:05 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Clint Tate ok cover u/g
ELE11-02855 Electrical Rough-In6/18/20126/19/20126/19/2012 1:59:56 PMPPASS
bud Phone #: ###-#### south wing walls west and lids ok cover
ELE12-01460 Temporary Service6/18/20126/19/20126/19/2012 1:15:56 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Paul Young t/s u/g n ok
ELE12-01459 Rough-In Permanent Service6/19/20126/19/20126/19/2012 12:11:28 PMPPASS
Please contact Virginia (Home Owner)@ ###-#### 30 min in advance for access. Please Final this Permit if ok at the same time. Thank you. Phone #: ###-#### >> Inspection requested via web by Clint Tate p/s u/g rec ok
ELE12-01141 Final6/18/20126/19/20126/19/2012 10:17:37 AMAPASS
AM Inspection please Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe ok final
ELE12-01459 Rough-In Permanent Service6/18/20126/19/20126/19/2012 10:09:55 AMACANC
Please contact Virginia (Home Owner)@ ###-#### 30 min in advance for access. Please Final this Permit if ok at the same time. Thank you. Phone #: ###-#### >> Inspection requested via web by Clint Tate Inspection cancelled from web by: Clint Tate
ELE12-01083 Final6/19/20126/19/20126/19/2012 9:55:42 AMAPASS
Contact: Brian Gee Phone #: ###-#### >> Inspection requested via web by Deb Gooden ok final
ELE12-01453 Rough-In Permanent Service6/18/20126/19/20126/19/2012 9:35:54 AMAPASS
Phone #: ###-#### >> Inspection requested via web by steve cooper corrections made, ri ok, p/s u/g n ok
ELE12-01164 Final6/18/20126/19/20126/19/2012 8:34:31 AMACANC
Jarod Phone #: ###-#### see ri
ELE12-01164 Electrical Rough-In6/19/20126/19/20126/19/2012 8:34:15 AMAPASS
Jarod Phone #: ###-#### potting and fence bonding ok
ELE12-00718 Final6/17/20126/19/20126/19/2012 8:32:57 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Paul White ok final, signed card