ELE18-02290
| Rough-In Permanent Service | 6/19/2018 | 6/19/2018 | 6/19/2018 2:54:07 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Hidajet Zahic Rough in ok cover p/s u/g n ok
|
ELE17-04353
| Electrical Rough-In | 6/19/2018 | 6/19/2018 | 6/19/2018 2:30:08 PM | P | PASS |
|
|
Job Foreman: Jay Karel Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Listing confirmed. Rough in ok
|
ELE18-00184
| Final | 6/19/2018 | 6/19/2018 | 6/19/2018 1:42:51 PM | P | PASS |
|
|
For access please call Don 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott No card posted Final ok
|
ELE18-02200
| Temporary Service | 6/18/2018 | 6/19/2018 | 6/19/2018 11:56:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE18-02285
| Rough-In Permanent Service | 6/18/2018 | 6/19/2018 | 6/19/2018 11:41:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE18-02291
| Electrical Rough-In | 6/19/2018 | 6/19/2018 | 6/19/2018 11:12:46 AM | P | CANC |
|
|
Contact: Josh Mangum Phone #: ###-#### >> Inspection requested via web by Deb Gooden Inspection cancelled from web by: Deb Gooden
|
ELE18-01433
| Final | 6/18/2018 | 6/19/2018 | 6/19/2018 11:10:40 AM | A | PASS |
|
|
Garage access code 1001e Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE18-02249
| Temporary Service | 6/18/2018 | 6/19/2018 | 6/19/2018 10:55:51 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Charles Davis t/s u/g n ok
|
ELE18-02281
| Temporary Service | 6/18/2018 | 6/19/2018 | 6/19/2018 10:44:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Paula Gratiot t/s u/g n ok
|
ELE18-02277
| Temporary Service | 6/18/2018 | 6/19/2018 | 6/19/2018 10:43:48 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Paula Gratiot t/s u/g n ok
|
ESC18-00193
| Random Inspection | 6/19/2018 | 6/19/2018 | 6/19/2018 10:43:00 AM | P | FAIL |
|
|
Inlets to north of lots no protection. Will check 6-26-18 for completion.
|
ELE18-02282
| Temporary Service | 6/18/2018 | 6/19/2018 | 6/19/2018 10:27:33 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Paula Gratiot t/s u/g n ok
|
ELE18-01775
| Electrical Rough-In | 6/18/2018 | 6/19/2018 | 6/19/2018 10:16:56 AM | A | PASS |
|
|
Remaining underground for swimming pool Phone #: ###-#### Inspection requested via web by Lars Johnson Rough in ok cover
|
ELE18-01513
| Electrical Rough-In | 6/18/2018 | 6/19/2018 | 6/19/2018 10:03:58 AM | A | PASS |
|
|
Swimming pool/spa EQ bonding plane wiring ; connections Phone #: ###-#### Inspection requested via web by Lars Johnson EQ bond pool and hot tub rough in ok cover
|
ELE18-02290
| Rough-In Permanent Service | 6/18/2018 | 6/19/2018 | 6/19/2018 9:47:35 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Hidajet Zahic 110.3- Unable to confirm listing for non-metallic pancake boxes on exterior. Provde documentation. 210.52- A receptacle outlet shall be located with in 6' of flex room door to patio. nearest one 8'. 300.4 (A)(1)- Cables passing thru holes that do not meaintain 1 1/4" from framing surface they shall be protected from damage by nail plates. Marked with X. 300.4 (B)(1)- Where NM cable enter fireplace it shall be protected by a bushd fitting. 300.4(G)- Where #4 or larger enter an enclosure they shall enter thru a bushed fitting. Check smoke detector locations, unable to locate print to confirm. complete make-up, fireplace switches, wirenuts missing switch near office stair.
|