Inspections for the day of: Tuesday, June 2, 1998.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRuss Owen
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD98-00938 INSP - Energy code compliance6/1/19986/2/19986/3/1998 12:00:00 AMAPART
06/02/98 407 - still need to ad high R at garage warm wall.
BLD98-00839 INSP - Framing/Rough-in6/2/19986/2/19986/3/1998 12:00:00 AMPPART
06/02/98 407 - left corrections.nd framing/ ###-####
MEC98-01739 INSP - Final6/1/19986/2/19986/3/1998 12:00:00 AMPNR
06/02/98 407 - not ready will need to recall inspection.
MEC98-01739 INSP - Final6/1/19986/2/19986/3/1998 12:00:00 AMPNR
06/02/98 407 - not ready will need to recall inspection.
BLD98-00938 INSP - Energy code compliance6/2/19986/2/19986/2/1998 12:00:00 AM FAIL
/ / 407 - Need to add some vapor barrier in some locations.
BLD98-01027 INSP - Framing/Rough-in6/1/19986/2/19986/2/1998 12:00:00 AMAPASS
06/02/98 407 - Scheduled by Hello!. Contact phone is [8666175].
BLD98-00938 INSP - Framing/Rough-in6/1/19986/2/19986/2/1998 12:00:00 AMAPASS
06/02/98 407 - REINSPECTION ON FRAMING /DOLLAND ###-####
BLD96-02798 INSP - Final6/2/19986/2/19986/2/1998 12:00:00 AMAPART
found electrical conduit sleves thru walls appear to have been fire stoped incorrectly,i notified Ormand and the Electrical contractor.
BLD97-02769 INSP - Framing/Rough-in6/1/19986/2/19986/2/1998 12:00:00 AMACANC
06/02/98 407 - trans to 301.
BLD98-00661 INSP - Framing/Rough-in6/1/19986/2/19986/2/1998 12:00:00 AMAPASS
06/02/98 407 - ###-####
MEC98-01113 INSP - Final6/1/19986/2/19986/2/1998 12:00:00 AMACANC
06/02/98 407 - transfer to 301.
MEC98-01113 INSP - Final6/1/19986/2/19986/2/1998 12:00:00 AMACANC
06/02/98 407 - transfer to 301.
MEC98-01589 INSP - Framing/ Rough-in6/1/19986/2/19986/2/1998 12:00:00 AMACANC
06/02/98 407 - trans to 301. 445].
MEC98-01687 INSP - Framing/ Rough-in6/2/19986/2/19986/2/1998 12:00:00 AMPCANC
06/02/98 407 - trans to 301.
MEC98-01696 INSP - Framing/ Rough-in6/2/19986/2/19986/2/1998 12:00:00 AMPPASS
gas log stove and pressure test.
MEC98-00306 INSP - Final6/2/19986/2/19986/2/1998 12:00:00 AMPFAIL
06/02/98 407 - left a correction.!. Contact phone is [3756101].
MEC98-00306 INSP - Final6/2/19986/2/19986/2/1998 12:00:00 AMPFAIL
06/02/98 407 - left a correction.!. Contact phone is [3756101].
BLD98-01431 INSP - Foundation6/2/19986/2/19986/2/1998 12:00:00 AMPPART
06/02/98 407 - john ###-####- Footings have been poured with out approval,They called me to go out for a foundation wall today wanted me there late as possible,at 4:45pm they are about 80% complete with the walls,No approved plans on site,work appears to be out of the set backs and the walls have rebar at the garage fronts along with a continous footing. wall width is per the print at the site.