Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-01863 Electrical Rough-In6/2/20206/2/20206/2/2020 3:46:18 PMPFAIL
building vacant. call for key code. Phone #: ###-#### Inspection requested via web by David McClellan
BCC- A city approved set of prints shall be on site prior to an inspection.

330.30- MC support and secure on east wall has been taken apart to add studs. Wiring hanging, boxes not secured, mudrings removed. General contractor trying to repair illegally.
517.13- Exam and treatment areas shall have an effective grounding path as per 250.118.
ELE20-01869 Electrical Rough-In6/2/20206/2/20206/2/2020 3:02:28 PMPPASS
5433. Lockbox in hallway on fire extinguisher box Phone #: ###-#### Inspection requested via web by Dean Gernaat
City approved set of print on site.
Conference room shall comply with 210.71. 375 square foot room will require 2 floor receptacles and 7 minimum total receptacles.
Wall rough in ok cover.
ELE20-00389 Final6/2/20206/2/20206/2/2020 2:07:25 PMPPASS
Thank you Phone #: ###-#### Inspection requested via web by Eric Brown Final ok
ELE20-01769 Temporary Service6/2/20206/2/20206/2/2020 1:24:03 PMPFAIL
Contact: Damonn Barr Phone #: ###-#### Inspection requested via web by Deb Gooden 550.4- Mobile job trailers shall comply with article 550 for power supply.
550.32- Service equipment shall be located adjacent to unit it serves and not be located in or on unit.
ELE19-03913 Final6/2/20206/2/20206/2/2020 12:48:54 PMPPASS
Install EMC sign above Jump parking garge enterance on 11th street. All Primary Power by others Phone #: ###-#### Inspection requested via web by Ken Olsen Final ok
ELE19-00601 Electrical Rough-In6/1/20206/2/20206/2/2020 10:50:28 AMAPASS
6th floor guest rooms cover. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen
602 thru 624 baths, HVAC, hardlids rough in ok cover
ELE20-01395 Rough-In Permanent Service6/1/20206/2/20206/2/2020 9:37:24 AMAPASS
It will be open. If you have any questions please feel free to contact ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Rough in ok cover p/s o/h n ok
ELE20-01393 Rough-In Permanent Service6/1/20206/2/20206/2/2020 9:36:10 AMAPASS
It will be open. If you have any questions please feel free to contact ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan
Rough in ok cover p/s o/h n ok