Inspections for the day of: Tuesday, June 20, 2006.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04025 ELE-Aging Inspection6/20/20066/20/20066/23/2006 4:39:39 PM NR
called, he will try to get in next 2 weeks
ELE06-00548 Final6/20/20066/20/20066/20/2006 4:26:08 PMPPASS
dan; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to final
ELE05-00588 Final6/20/20066/20/20066/20/2006 3:47:52 PMPPASS
chris; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
ELE06-01187 ELE-Aging Inspection6/20/20066/20/20066/20/2006 3:34:54 PM DONE
suc
ELE05-03533 Final6/20/20066/20/20066/20/2006 2:45:47 PMPFAIL
###-#### - mike met cntr, left corr notice, nec 410.15(B)(3)(a) ground terminal shall be accessible from the handhole,410.15(B)(1) handholes shall have raintight covers
ELE06-00117 Final6/20/20066/20/20066/20/2006 2:37:55 PMPCANC
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles wrong permit number
ELE06-00116 Final6/20/20066/20/20066/20/2006 2:37:23 PMPFAIL
BCC 4-05-33(A)(B) equipment shall be listed and labelled by a nationally recognized testing lab (air comp)
ELE06-02268 Permanent Service6/20/20066/20/20066/20/2006 2:19:47 PMPPASS
dick ###-#### call 1st before insp for access p/s o/h rec ok
ELE06-02278 Rough-In Permanent Service6/20/20066/20/20066/20/2006 1:05:15 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dan Rohl ric ok, p/s u/g n ok
ELE06-01642 Final6/20/20066/20/20066/20/2006 11:50:45 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook ok to final, signed card
ELE06-01452 Final6/20/20066/20/20066/20/2006 11:36:30 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook ok to final, signed card
ELE05-04540 Final6/20/20066/20/20066/20/2006 10:21:40 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook ok to final, signed struct card
ELE06-01972 Electrical Rough-In6/19/20066/20/20066/20/2006 9:46:45 AMAPART
Ceiling cover rough-in, please contact Dan W. thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters called contr, NO CEILINGS READY, looked at walls instead. north 2 offices and divider wall ok to cover only
ELE06-02247 Electrical Rough-In6/19/20066/20/20066/20/2006 9:20:10 AMAFAIL
rough in on 1 room, house is vacant and either back or front door will be open. Any questions call Tate @ ###-#### Internet Inspection Request from: Andy Rose called, left message, left corr notice, nec 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing member,210.52(A)(1) recpt shall be installed so that no point along floor line in wall space is more than 6' from a recpt, BCC no violations shall be retained
ELE06-02230 Rough-In Permanent Service6/16/20066/20/20066/20/2006 8:51:26 AMAFAIL
steve ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called, left message, nec 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing member,314.20 in walls of combustible material, boxes shall be flush with finished surface or project therefrom.
ELE06-00159 Final6/20/20066/20/20066/20/2006 7:45:15 AMPCANC
Scheduled by a contractor via Hello! on 6/20/2006 at 5:57:10 AM. Contact: ###-####. Inspection cancelled from web by: Marsha Smylie