ELE12-02592
| ELE-Aging Inspection | 6/20/2016 | 6/20/2016 | 6/23/2016 11:09:20 AM | | CANC |
|
|
too busy
|
ELE12-02616
| ELE-Aging Inspection | 6/20/2016 | 6/20/2016 | 6/23/2016 11:07:53 AM | | CANC |
|
|
too busy
|
ELE16-00296
| Final | 6/20/2016 | 6/20/2016 | 6/20/2016 2:21:47 PM | P | PASS |
|
|
Lock box code 2009 Phone #: ###-#### Inspection requested via web by Robert Schroder Final ok
|
ELE16-00295
| Final | 6/20/2016 | 6/20/2016 | 6/20/2016 2:19:02 PM | P | PASS |
|
|
Lock box code 2009 Phone #: ###-#### Inspection requested via web by Robert Schroder Final ok
|
ELE16-01945
| Electrical Rough-In | 6/20/2016 | 6/20/2016 | 6/20/2016 2:10:41 PM | P | PASS |
|
|
would like call ahead; Phone #: ###-#### New office area to the rite walls only ok cover
|
ELE15-03736
| Electrical Rough-In | 6/20/2016 | 6/20/2016 | 6/20/2016 1:38:28 PM | P | PASS |
|
|
Rocky Phone #: ###-#### undrground to shop shop/detached garage ok cover
|
ELE15-03736
| Permanent Service | 6/20/2016 | 6/20/2016 | 6/20/2016 1:38:16 PM | P | FAIL |
|
|
Rocky Phone #: ###-#### as per 250 shall not bond grounded and grounding conductor more then once and shall not use grounding conductor as grounded(paralled equip&grounded conductors)
|
ESC15-01070
| Site Final | 6/20/2016 | 6/20/2016 | 6/20/2016 12:59:12 PM | P | PASS |
|
|
site final ok
|
ESC15-01073
| Site Final | 6/20/2016 | 6/20/2016 | 6/20/2016 12:57:40 PM | P | PASS |
|
|
site final ok
|
ESC15-01068
| Site Final | 6/20/2016 | 6/20/2016 | 6/20/2016 12:56:44 PM | P | PASS |
|
|
site final ok
|
ELE16-01925
| Electrical Rough-In | 6/18/2016 | 6/20/2016 | 6/20/2016 10:19:49 AM | A | PART |
|
|
Please call Adam @ ###-#### for access. Thank you! Phone #: ###-#### Inspection requested via web by Adam Staigle Partial Marked on contractor print grid rough in ok cover
|
ELE16-01614
| Electrical Rough-In | 6/17/2016 | 6/20/2016 | 6/20/2016 9:34:47 AM | A | FAIL |
|
|
Suite 170 Misc. electrical rough-in. If that suite is locked, the tenants next door in suite 180 have access. Phone #: ###-#### Inspection requested via web by Jonathan Poot 410.36(b) luminaires in suspended cielings shall securely attached to building structure
|
ELE16-01929
| Temporary Service | 6/17/2016 | 6/20/2016 | 6/20/2016 8:58:10 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE16-01930
| Temporary Service | 6/17/2016 | 6/20/2016 | 6/20/2016 8:57:33 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE16-01931
| Temporary Service | 6/17/2016 | 6/20/2016 | 6/20/2016 8:55:49 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE16-01932
| Temporary Service | 6/17/2016 | 6/20/2016 | 6/20/2016 8:55:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE16-01923
| Electrical Rough-In | 6/17/2016 | 6/20/2016 | 6/20/2016 8:21:41 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terry Scott Master bath and floor heat ok cover
|