ELE17-00848
| Electrical Rough-In | 6/19/2017 | 6/20/2017 | 6/20/2017 1:27:32 PM | P | PASS |
|
|
johnny - call 30 mins prior Phone #: ###-#### Ok cover small addition mstr.
|
ELE17-00842
| Final | 6/20/2017 | 6/20/2017 | 6/20/2017 1:04:08 PM | P | PASS |
|
|
Garage code is 1994 Phone #: ###-#### Inspection requested via web by Shaun Kirkman Ok final
|
ELE17-01161
| Electrical Rough-In | 6/20/2017 | 6/20/2017 | 6/20/2017 12:34:07 PM | P | PASS |
|
|
Please inspect master bathroom floor heat. Thank you Shaun Phone #: ###-#### Inspection requested via web by Shaun Kirkman Ok cover floor heat.
|
ELE17-01938
| Temporary Service | 6/20/2017 | 6/20/2017 | 6/20/2017 12:28:44 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Shaun Kirkman t/s u/g n ok
|
ELE17-01837
| Electrical Rough-In | 6/20/2017 | 6/20/2017 | 6/20/2017 12:06:37 PM | P | PASS |
|
|
Ufer ground inspection. Please inspect before 3:30 if possible please. Concrete is showing up then. Thank you! Phone #: ###-#### Inspection requested via web by Tom Jenkins Ok cover. 1/0 copper used.
|
ELE17-01557
| Permanent Service | 6/19/2017 | 6/20/2017 | 6/20/2017 11:54:49 AM | P | PASS |
|
|
ryan Phone #: ###-#### p/s o/h rec ok. New service location off alley needs fed with existing OH drop to residance.
|
ELE17-01882
| Electrical Rough-In | 6/20/2017 | 6/20/2017 | 6/20/2017 11:34:01 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Ok cover. EQ bonding. 8 locations on long sides of pool have rebar formed into pool for lifting purposes. All locations have been tagged off EQ ring. 1 steel I-beam also bonded on N side of pool down low. 1 bond for auto cover.
|
ELE17-01930
| Electrical Rough-In | 6/19/2017 | 6/20/2017 | 6/20/2017 11:15:00 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson Ok cover
|
ELE17-00622
| Final | 6/20/2017 | 6/20/2017 | 6/20/2017 11:02:38 AM | P | PASS |
|
|
Someone should be there from 10am on. Please call if you have any questions. Thank you Shaun Phone #: ###-#### Inspection requested via web by Shaun Kirkman Ok final
|
ELE17-01706
| Electrical Rough-In | 6/15/2017 | 6/20/2017 | 6/20/2017 10:25:23 AM | A | PASS |
|
|
Call one hour before arrival. Thanks Phone #: ###-#### Inspection requested via web by Christian Kilpatrick Ok cover. All items UL listed.
|
ELE17-00901
| Final | 6/19/2017 | 6/20/2017 | 6/20/2017 9:23:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Ok final
|
ELE17-01706
| Rough-In Permanent Service | 6/15/2017 | 6/20/2017 | 6/20/2017 9:04:14 AM | A | CANC |
|
|
Service upgrade inspection for re-energize Phone #: ###-#### Inspection requested via web by Christian Kilpatrick Service wont be ready until 6/21/17
|
ELE17-00234
| Electrical Rough-In | 6/19/2017 | 6/20/2017 | 6/20/2017 8:49:57 AM | A | PASS |
|
|
master bath floor heat. inspect for cover Phone #: ###-#### Inspection requested via web by brian morrow ok cover
|
ELE13-02063
| ELE-Aging Inspection | 6/20/2017 | 6/20/2017 | 6/20/2017 7:32:07 AM | | PASS |
|
|
No final inspection requested at this time.
|