Inspections for the day of: Tuesday, June 20, 2017.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01429 Electrical Rough-In6/20/20176/20/20176/20/2017 2:13:13 PMPPASS
Phone #: ###-#### Inspection requested via web by Jason Wicks
Suspended ceilings only ok cover
ELE17-01912 Permanent Service6/20/20176/20/20176/20/2017 2:06:19 PMPPASS
We Are Changing The Service Today But We Can''t Get Our Disconnect Until 11:00 So We Won''t Be Ready Until Like 2:00 So If You Can Work That Out Awesome Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett
p/s o/h rec ok
ELE17-01936 Electrical Rough-In6/20/20176/20/20176/20/2017 1:35:29 PMPPASS
John-ground work Phone #: ###-####
u/g for temp power for parking lot from transformer to service location ok cover
ELE17-00344 Final6/20/20176/20/20176/20/2017 1:14:14 PMPFAIL
Phone #: ###-#### Inspection requested via web by dennis mcneely
210.8 Receptacles located within 6' of a sink shall have GFCI protection
210.52 (c)(1) shall be a receptacle located within 24" of edge of counter
110.25 Lockout for micro/range/hood
Missing outlet for washing machine and plate cover for dryer
ELE17-01220 Electrical Rough-In6/20/20176/20/20176/20/2017 12:47:43 PMPPASS
Floor heat rough in Phone #: ###-#### Inspection requested via web by Emmet Bushman
Master bath floor heat ok cover
ELE16-01134 Electrical Rough-In6/19/20176/20/20176/20/2017 10:57:42 AMAPASS
3rd Floor Pool and fitness room rough in. Please call Bobby ###-####. Phone #: ###-#### Inspection requested via web by Clint Tate
3rd floor pool area hard lid ceilings and fitness area walls ok cover
ELE17-00384 Final6/19/20176/20/20176/20/2017 9:35:50 AMAFAIL
Monic Phone #: ###-####-please call for access code
210.12 (d) /branch circuit extensions shall have AFCI protection
408.7 Unused openings shall be closed
ELE17-01928 Rough-In Permanent Service6/19/20176/20/20176/20/2017 9:01:41 AMACANC
Phone #: ###-####-grounding and reconnect- Inspection requested via web by Eric Schroeder
Just needed p/s
ELE17-01928 Permanent Service6/20/20176/20/20176/20/2017 9:01:19 AMPPASS
Phone #: ###-####-grounding and reconnect- Inspection requested via web by Eric Schroeder
Will need to see main breaker secured in place for final.
p/s o/h rec ok
ELE17-01929 Rough-In Permanent Service6/19/20176/20/20176/20/2017 8:50:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Mike Okamura
Detached garage ok cover
p/s u/g n ok