ELE17-01429
| Electrical Rough-In | 6/20/2017 | 6/20/2017 | 6/20/2017 2:13:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks Suspended ceilings only ok cover
|
ELE17-01912
| Permanent Service | 6/20/2017 | 6/20/2017 | 6/20/2017 2:06:19 PM | P | PASS |
|
|
We Are Changing The Service Today But We Can''t Get Our Disconnect Until 11:00 So We Won''t Be Ready Until Like 2:00 So If You Can Work That Out Awesome Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett p/s o/h rec ok
|
ELE17-01936
| Electrical Rough-In | 6/20/2017 | 6/20/2017 | 6/20/2017 1:35:29 PM | P | PASS |
|
|
John-ground work Phone #: ###-#### u/g for temp power for parking lot from transformer to service location ok cover
|
ELE17-00344
| Final | 6/20/2017 | 6/20/2017 | 6/20/2017 1:14:14 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by dennis mcneely 210.8 Receptacles located within 6' of a sink shall have GFCI protection 210.52 (c)(1) shall be a receptacle located within 24" of edge of counter 110.25 Lockout for micro/range/hood Missing outlet for washing machine and plate cover for dryer
|
ELE17-01220
| Electrical Rough-In | 6/20/2017 | 6/20/2017 | 6/20/2017 12:47:43 PM | P | PASS |
|
|
Floor heat rough in Phone #: ###-#### Inspection requested via web by Emmet Bushman Master bath floor heat ok cover
|
ELE16-01134
| Electrical Rough-In | 6/19/2017 | 6/20/2017 | 6/20/2017 10:57:42 AM | A | PASS |
|
|
3rd Floor Pool and fitness room rough in. Please call Bobby ###-####. Phone #: ###-#### Inspection requested via web by Clint Tate 3rd floor pool area hard lid ceilings and fitness area walls ok cover
|
ELE17-00384
| Final | 6/19/2017 | 6/20/2017 | 6/20/2017 9:35:50 AM | A | FAIL |
|
|
Monic Phone #: ###-####-please call for access code 210.12 (d) /branch circuit extensions shall have AFCI protection 408.7 Unused openings shall be closed
|
ELE17-01928
| Rough-In Permanent Service | 6/19/2017 | 6/20/2017 | 6/20/2017 9:01:41 AM | A | CANC |
|
|
Phone #: ###-####-grounding and reconnect- Inspection requested via web by Eric Schroeder Just needed p/s
|
ELE17-01928
| Permanent Service | 6/20/2017 | 6/20/2017 | 6/20/2017 9:01:19 AM | P | PASS |
|
|
Phone #: ###-####-grounding and reconnect- Inspection requested via web by Eric Schroeder Will need to see main breaker secured in place for final. p/s o/h rec ok
|
ELE17-01929
| Rough-In Permanent Service | 6/19/2017 | 6/20/2017 | 6/20/2017 8:50:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura Detached garage ok cover p/s u/g n ok
|