ELE05-01745
| Conference | 6/21/2005 | 6/21/2005 | 6/21/2005 4:20:51 PM | P | DONE |
|
|
Scheduled by a contractor via Hello! on 6/21/2005 at 7:33:21 AM. Contact: ###-####. talked about getting p/s to work on house
|
ELE05-02168
| Final | 6/20/2005 | 6/21/2005 | 6/21/2005 3:58:42 PM | P | PASS |
|
|
dale ###-#### ok to final
|
ELE04-03760
| Final | 6/21/2005 | 6/21/2005 | 6/21/2005 3:58:02 PM | P | PASS |
|
|
PLease call prior to inspection so he can make sure you can get in////mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to final
|
ELE05-01399
| Electrical Rough-In | 6/21/2005 | 6/21/2005 | 6/21/2005 2:35:01 PM | P | PART |
|
|
skip; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to partially cover soffits, need to look at fixtures before cover
|
ELE05-01972
| Electrical Rough-In | 6/20/2005 | 6/21/2005 | 6/21/2005 2:32:49 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 6/20/2005 at 8:04:03 PM. Contact: ###-####. told builder, left corr notice,300.4(B)(2),(D) nm cable shall be 1 1/4" from edge of framing member, 334.30 nm cable shall be stapled within 8" of box, 314.17(A),110.12(A) openings in boxes shall be closed, 250.110, metal boxes shall be grounded,110.14(A) splices shall use identified devices
|
ELE05-02200
| Electrical Rough-In | 6/21/2005 | 6/21/2005 | 6/21/2005 1:17:47 PM | P | PASS |
|
|
please call 30-15 min prior for access///grant; Phone #:###-#### Internet Inspection Request from: Letitia Mesa called contr to add box for front recpt and light out back door, signed insp card for ri, left green sticker, ric ok
|
ELE05-02168
| Permanent Service | 6/20/2005 | 6/21/2005 | 6/21/2005 12:44:14 PM | P | PASS |
|
|
dale ###-#### p/s u/g exst ok
|
ELE05-02169
| Permanent Service | 6/20/2005 | 6/21/2005 | 6/21/2005 11:40:03 AM | A | CANC |
|
|
please call prior to inspection so he can meet ya there///###-#### shawn was for conf
|
ELE05-01024
| Electrical Rough-In | 6/20/2005 | 6/21/2005 | 6/21/2005 9:40:04 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 6/20/2005 at 11:35:27 PM. Contact: ###-####. ok to pour concrete encased electrode, will call before backfill
|
ELE05-02183
| Rough-In Permanent Service | 6/20/2005 | 6/21/2005 | 6/21/2005 8:48:37 AM | A | PASS |
|
|
brandon ###-#### ric ok, p/s u/g n ok
|
ELE05-02188
| Rough-In Permanent Service | 6/20/2005 | 6/21/2005 | 6/21/2005 8:26:00 AM | A | FAIL |
|
|
dean-- ###-#### called contr, left corr notice, 250.24(A) gec shall be connected to grounded service conductor at service
|
ELE05-02169
| Conference | 6/21/2005 | 6/21/2005 | 6/21/2005 12:00:00 AM | A | DONE |
|
|
please call prior to inspection so he can meet ya there///###-#### met with elect to talk about service
|