Inspections for the day of: Tuesday, June 21, 2005.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01745 Conference6/21/20056/21/20056/21/2005 4:20:51 PMPDONE
Scheduled by a contractor via Hello! on 6/21/2005 at 7:33:21 AM. Contact: ###-####. talked about getting p/s to work on house
ELE05-02168 Final6/20/20056/21/20056/21/2005 3:58:42 PMPPASS
dale ###-#### ok to final
ELE04-03760 Final6/21/20056/21/20056/21/2005 3:58:02 PMPPASS
PLease call prior to inspection so he can make sure you can get in////mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to final
ELE05-01399 Electrical Rough-In6/21/20056/21/20056/21/2005 2:35:01 PMPPART
skip; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to partially cover soffits, need to look at fixtures before cover
ELE05-01972 Electrical Rough-In6/20/20056/21/20056/21/2005 2:32:49 PMPFAIL
Scheduled by a contractor via Hello! on 6/20/2005 at 8:04:03 PM. Contact: ###-####. told builder, left corr notice,300.4(B)(2),(D) nm cable shall be 1 1/4" from edge of framing member, 334.30 nm cable shall be stapled within 8" of box, 314.17(A),110.12(A) openings in boxes shall be closed, 250.110, metal boxes shall be grounded,110.14(A) splices shall use identified devices
ELE05-02200 Electrical Rough-In6/21/20056/21/20056/21/2005 1:17:47 PMPPASS
please call 30-15 min prior for access///grant; Phone #:###-#### Internet Inspection Request from: Letitia Mesa called contr to add box for front recpt and light out back door, signed insp card for ri, left green sticker, ric ok
ELE05-02168 Permanent Service6/20/20056/21/20056/21/2005 12:44:14 PMPPASS
dale ###-#### p/s u/g exst ok
ELE05-02169 Permanent Service6/20/20056/21/20056/21/2005 11:40:03 AMACANC
please call prior to inspection so he can meet ya there///###-#### shawn was for conf
ELE05-01024 Electrical Rough-In6/20/20056/21/20056/21/2005 9:40:04 AMAPASS
Scheduled by a contractor via Hello! on 6/20/2005 at 11:35:27 PM. Contact: ###-####. ok to pour concrete encased electrode, will call before backfill
ELE05-02183 Rough-In Permanent Service6/20/20056/21/20056/21/2005 8:48:37 AMAPASS
brandon ###-#### ric ok, p/s u/g n ok
ELE05-02188 Rough-In Permanent Service6/20/20056/21/20056/21/2005 8:26:00 AMAFAIL
dean-- ###-#### called contr, left corr notice, 250.24(A) gec shall be connected to grounded service conductor at service
ELE05-02169 Conference6/21/20056/21/20056/21/2005 12:00:00 AMADONE
please call prior to inspection so he can meet ya there///###-#### met with elect to talk about service