Inspections for the day of: Wednesday, June 21, 2006.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00069 Final6/21/20066/21/20066/21/2006 4:39:40 PMPPASS
neil; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok
ELE06-00101 Final6/21/20066/21/20066/21/2006 4:39:15 PMPPASS
neil; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok
ELE06-02014 Electrical Rough-In6/21/20066/21/20066/21/2006 4:01:34 PMPPART
Scheduled by a contractor via Hello! on 6/21/2006 at 9:15:47 AM. Contact: ###-####. all walls ok
ELE06-01919 Electrical Rough-In6/21/20066/21/20066/21/2006 3:30:22 PMPFAIL
melissa; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
corr. all violations not corrected new ones created, 300.4 nail plates and 11/4", 300.14 6" free length, 110.14(B) shall use devices to splices cannot just twist them, new violation 314.17(C) and 334.30 secure cables within 8" of boxes, Jim S is at site too talk to owner about corrections job still needs r/i for other bath rm afci for bed rm circuits, guy for mast, grd pigtails for switches
ELE06-02267 Permanent Service6/21/20066/21/20066/21/2006 2:45:51 PMPPASS
phil; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s o/h rec. ok
ELE06-02297 Final6/21/20066/21/20066/21/2006 2:20:52 PMPPASS
pat ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok
ELE06-02044 Permanent Service6/21/20066/21/20066/21/2006 1:51:48 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Joe Thomas p/s o/h rec. ok
ELE06-02226 Electrical Rough-In6/20/20066/21/20066/21/2006 1:35:40 PMPFAIL
daniel - call 1/2 hr prior for access reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. fee due called,250.24 all GEC and water bonds shall be at p/s not subpanel, 250.52(A)(1)or 104(A)(1) grd or bond water system, 250.53(G) grd rods shall be 6ft apart, 250.50 where present all electrodes shall be bonded together (old grd rod left of back porch, 250.64(C) shall not splice GEC and remove it from conduit and the subpanel
ELE06-02228 Permanent Service6/21/20066/21/20066/21/2006 12:50:24 PMPPASS
My cell number is ###-####. Thanks Randy; Phone #: ###-#### Internet Inspection Request from: Randy Fletcher p/s o/h rec. ok
ELE06-02228 Final6/21/20066/21/20066/21/2006 12:50:04 PMPPASS
My cell number is ###-####. Thanks Randy; Phone #: ###-#### Internet Inspection Request from: Randy Fletcher
ELE06-01420 Final6/21/20066/21/20066/21/2006 12:10:18 PMPPASS
rick; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok
ELE06-00990 ELE-Aging Inspection6/21/20066/21/20066/21/2006 10:38:05 AM DONE
ELE06-00990 Final6/21/20066/21/20066/21/2006 10:37:53 AMAPASS
ok looked at it last friday
ELE06-01525 Final6/21/20066/21/20066/21/2006 10:36:01 AMPPASS
darrell; Phone #: ###-#### Internet Inspection Request from: Darla Downs ok survey posted called 240.24 disconnect switch for garage shall not be higher than 6ft 7"
ELE06-01324 Permanent Service6/20/20066/21/20066/21/2006 10:12:18 AMAPASS
Lynn; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
p/s u/g new ok
ELE06-02058 Permanent Service6/20/20066/21/20066/21/2006 10:06:24 AMAPASS
andy - space #5 REINSP; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s o/h new ok
ELE06-02058 Final6/21/20066/21/20066/21/2006 10:05:59 AMAPASS
andy - space #5 REINSP; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
ELE06-02044 Permanent Service6/20/20066/21/20066/21/2006 9:20:24 AMAFAIL
Panel In Basement. Back door will be unlocked; Phone #: ###-#### Internet Inspection Request from: Joe Thomas
corr. needs 2" rigid or IMC for mast called
ELE06-02237 Permanent Service6/20/20066/21/20066/21/2006 8:12:58 AMAPASS
reinspection on service. any questions call George @###-#### Internet Inspection Request from: Andy Rose p/s o/h rec. ok
ELE06-02237 Final6/21/20066/21/20066/21/2006 8:10:44 AMAPASS
reinspection on service. any questions call George @###-#### Internet Inspection Request from: Andy ok