Inspections for the day of: Wednesday, June 21, 2006.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD04-00845 BLD-Aging Inspection6/21/20066/21/20066/22/2006 11:23:26 AM CANC
BLD04-03025 BLD-Framing/Rough-in6/21/20066/21/20066/21/2006 5:19:51 PMPPASS
Scheduled by a contractor via Hello! on 6/21/2006 at 8:02:57 AM. Contact: ###-####. Insul. in 3rd floor rooms south wing. ok to rock walls
BLD06-01380 BLD-Final6/20/20066/21/20066/21/2006 3:04:15 PMPPASS
pete; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Final ok.
BLD06-01730 BLD-Footing6/20/20066/21/20066/21/2006 2:33:30 PMPCANC
TERRY- LATE AS POSSIBLE; Phone #: ###-#### Internet Inspection Request from: Darla Downs
BLD06-00007 BLD-Framing/Rough-in6/21/20066/21/20066/21/2006 2:23:38 PMPFAIL
duncan ###-####. Southwall not per approved UL listing for 2hr. wall. Contractor to get alternate method from architect if possible.
BLD06-00769 BLD-Framing/Rough-in6/20/20066/21/20066/21/2006 12:16:05 PMAFAIL
John King; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. needs to add double layer 5/8" typex above sheet metal plenum in hall way, and drop supply line out of floor/ceiling assembly or install two layers of 5/8" type X in between floor joist.
BLD06-00879 BLD-Footing6/20/20066/21/20066/21/2006 11:29:25 AMAPASS
They will be pouring at 11am. If you have any questions please call Greg Bolton @ ###-####. Thanks; Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson. elevator pit.
BLD05-02585 BLD-Final6/20/20066/21/20066/21/2006 11:12:49 AMAPEND
Floyd; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt Everything ok, will issue cert of compliance once shell and core is sugned off.
BLD05-02584 BLD-Final6/20/20066/21/20066/21/2006 11:11:49 AMAPEND
Please call prior to inspection so he can open for you-floyd; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt. Everyuthing ok, need final aff. letter from special insp. agency prior to issuing a cert of compliance.
BLD05-02329 BLD-Framing/Rough-in6/20/20066/21/20066/21/2006 10:48:49 AMAFAIL
jay; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Shaft enclosure required for B vent from ground unit to underside of roof deck to to 1hr penetration of floor ceiling assembly. Complete all fire caulking/ install puddypads at 1hr. wall on elec. boxes. provide approved fix for broken top chords and oversized holes on floorjoist. No wood penetrations allowed on 1hr. wall.
BLD05-02328 BLD-Framing/Rough-in6/20/20066/21/20066/21/2006 10:45:11 AMAFAIL
jay; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Shaaft enclosure required for B vent from ground unit to underside of roof deck due to 1hr penetration of floor ceiling assembly. Complete all firecaulking/ install puddypads on elec. boxes at 1 hr. wall. Provide approved fix for broken top chords and oversized holes on floor joist. No wood penetrations allowed on 1hr. walls.
BLD06-00827 BLD-Framing/Rough-in6/20/20066/21/20066/21/2006 9:28:55 AMAPASS
Scheduled by a contractor via Hello! on 6/20/2006 at 12:47:34 PM. Contact: ###-####.
BLD05-02168 BLD-Energy code compliance6/20/20066/21/20066/21/2006 8:59:30 AMAPASS
jock; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD05-02283 BLD-Final6/21/20066/21/20066/21/2006 8:20:11 AMAPASS
All issues resolved.
BLD05-02283 DOC - Permit Finaled6/21/20066/21/20066/21/2006 8:19:44 AMPPASS
BLD04-00479 BLD-Aging Inspection6/21/20066/21/20066/21/2006 8:12:11 AM DONE
BLD04-00479 DOC - Permit Finaled6/21/20066/21/20066/21/2006 8:12:02 AMPPASS
BLD06-01172 FIRE-Conference6/20/20066/21/20066/20/2006 12:21:49 PMACANC
Scheduled by a contractor via Hello! on 6/20/2006 at 12:13:29 PM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on Jun 20 2006 12:21PM.