Inspections for the day of: Thursday, June 22, 2006.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00883 ELE-Aging Inspection6/22/20066/22/20066/26/2006 9:54:34 AM DONE
ELE05-02730 ELE-Aging Inspection6/22/20066/22/20066/26/2006 9:23:43 AM PART
wsuc
ELE06-02267 Final6/22/20066/22/20066/22/2006 4:32:21 PMPNH
phil; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called
ELE06-02220 Rough-In Permanent Service6/22/20066/22/20066/22/2006 4:13:10 PMPFAIL
dhad; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
corr. called left message,110.3(B) and 225.36 needs main at garage, needs concrete encased electrode, 200.6 shall not ID 6 or smaller neutral, 300.4(D) 11/4"parallel to framing members, 410.4(A) needs fixture approved for outside, BCC remove devices from boxes so I can inspect, 250.104(C) bond building steel
ELE06-02069 Electrical Rough-In6/21/20066/22/20066/22/2006 3:29:44 PMPPART
Scheduled by a contractor via Hello! on 6/21/2006 at 4:50:21 PM. Contact: ###-####. walls and ceiling areas anop
ELE05-03868 Permanent Service6/20/20066/22/20066/22/2006 2:32:13 PMPPASS
clyde; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
p/s u/g rec. ok
ELE05-04648 Final6/22/20066/22/20066/22/2006 2:13:14 PMPFAIL
tracy - call 1/2 hr prior for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley 250.104 (A)(1) and T250.66 shall bond water system with #4 copper, and remove it from subpanel, 210.8(A)(5) gfci for recepts unfinished basement, 334.15 protect romex in unfinished basement where horizontal runs are called
ELE06-00833 Final6/22/20066/22/20066/22/2006 1:23:10 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot ok card signed
ELE06-02314 Electrical Rough-In6/22/20066/22/20066/22/2006 12:47:05 PMPPART
lloyd; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley walls ok
ELE06-01658 Permanent Service6/21/20066/22/20066/22/2006 11:50:56 AMAPASS
need perm service for power Internet Inspection Request from: Melyne Davis
p/s u/g new ok
ELE06-02320 Rough-In Permanent Service6/21/20066/22/20066/22/2006 10:57:31 AMAPASS
charlie Internet Inspection Request from: Melyne Davis r/i p/s u/g new ok
ELE06-00860 Electrical Rough-In6/21/20066/22/20066/22/2006 10:33:58 AMAFAIL
dan; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. met contr. 300.4 nail plates 11/4", 314.16 box fill 314.43 screws in boxes, 314.20 outside boxes shall be flush with siding, 210.11(C)(3) remove outlet in MB closet from bath circuit, 404.4 removeswitch from tub enclosure, 410.8 clearence MB closet, update permit for 10 rms
ELE06-01633 Final6/22/20066/22/20066/22/2006 9:51:58 AMAPASS
Please do a final inspection today. Thanks, Marvin; Phone #: ###-#### Internet Inspection Request from: Laura
ok card signed
ELE06-02238 Electrical Rough-In6/21/20066/22/20066/22/2006 9:04:49 AMAPART
scott - reinsp/please call1/2 hr prior to insp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley u/g ok
ELE06-01508 Final6/21/20066/22/20066/22/2006 8:36:42 AMAPASS
I believe everything is ready for you Mike thanks Brad; Phone #: ###-#### Internet Inspection Request from: Brad Baker ok card signed survey 210.8(B)(2) gfci for outlet north wall kit. 400.8(5) remove cord from ceiling called contractor will correct
ELE06-00856 Electrical Rough-In6/21/20066/22/20066/22/2006 8:11:58 AMAPART
sean - east end of aeronica - gate 589 ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok
ELE06-00300 Final6/22/20066/22/20066/22/2006 7:44:58 AMAPASS
PLEASE FINAL, ANOTHER CONTRACTOR IS FINISHING THE SWIMMING POOL; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack