ELE05-04025
| Electrical Rough-In | 6/22/2006 | 6/22/2006 | 6/23/2006 4:53:26 PM | P | CANC |
|
|
wrong action on wrong permit, see nr
|
ELE06-01002
| ELE-Aging Inspection | 6/22/2006 | 6/22/2006 | 6/23/2006 4:46:33 PM | | DONE |
|
|
called, left message to call
|
ELE06-01332
| Final | 6/22/2006 | 6/22/2006 | 6/22/2006 6:47:18 PM | P | FAIL |
|
|
steve; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called, left message, left corr notice, nec 210.8(A)(2) & (3) front recpt and garage recpt shall be gfci protected
|
ELE06-01367
| Final | 6/22/2006 | 6/22/2006 | 6/22/2006 6:45:13 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 6/22/2006 at 7:52:08 AM. Contact: ###-####. nec 406.5 &404.9 faceplates shall seat against finished surface,110.3(B) equipment shall be installed in accordance with instructions and operate,called, left survey, ok to final
|
ELE06-01580
| Final | 6/22/2006 | 6/22/2006 | 6/22/2006 6:42:10 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 6/22/2006 at 7:53:37 AM. Contact: ###-####. left survey, called contr, nec 406.5 and 404.9 faceplates shall seat against finished surface,406.4(D) recpt faces shall be flush with or project from faceplates, ok to final
|
ELE06-02316
| Final | 6/22/2006 | 6/22/2006 | 6/22/2006 3:41:03 PM | P | CANC |
|
|
dan; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley see ri
|
ELE06-02306
| Electrical Rough-In | 6/22/2006 | 6/22/2006 | 6/22/2006 3:25:43 PM | P | PASS |
|
|
ron - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr made, ric ok, p/s u/g n ok
|
ELE06-01706
| Final | 6/22/2006 | 6/22/2006 | 6/22/2006 3:24:43 PM | P | PASS |
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to final
|
ELE06-01776
| Final | 6/22/2006 | 6/22/2006 | 6/22/2006 3:23:57 PM | P | PASS |
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to final
|
ELE06-02161
| Temporary Service | 6/22/2006 | 6/22/2006 | 6/22/2006 1:14:44 PM | P | PASS |
|
|
oga; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles t/s u/g n ok
|
ELE06-00113
| Electrical Rough-In | 6/21/2006 | 6/22/2006 | 6/22/2006 11:45:16 AM | A | PART |
|
|
CONTACT: GREG PACK - 11TH FLOOR CEILING INSPECTION; Phone #: ###-#### Internet Inspection Request from: Deb McCoy 11th ceilings, #2 stairs 5-11 floor, lobby anop ok to cover
|
ELE06-02306
| Rough-In Permanent Service | 6/21/2006 | 6/22/2006 | 6/22/2006 10:35:34 AM | A | FAIL |
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called, left corr notice, nec 210.52(A)(1) recpts shall be installed so that no point is over 6' along wall space from a recpt outlet, 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing members,BCC all make-up shall be done
|
ELE06-02319
| Final | 6/21/2006 | 6/22/2006 | 6/22/2006 10:03:50 AM | A | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Shawna Hall called, wrong permit, they will recall
|
ELE06-02318
| Final | 6/21/2006 | 6/22/2006 | 6/22/2006 10:03:13 AM | A | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Shawna Hall wrong permit no, called , they will recall
|
ELE06-01313
| Permanent Service | 6/21/2006 | 6/22/2006 | 6/22/2006 9:21:38 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 6/21/2006 at 8:18:55 AM. Contact: ###-####. p/s exst meter pak n ok
|
ELE06-02290
| Rough-In Permanent Service | 6/21/2006 | 6/22/2006 | 6/22/2006 9:04:34 AM | A | PASS |
|
|
corrections have been made. ; Phone #: ###-#### Internet Inspection Request from: Shawna Hall corr made, ric ok, p/s u/g n ok
|
ELE06-00159
| Final | 6/22/2006 | 6/22/2006 | 6/22/2006 8:50:57 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 6/22/2006 at 6:15:47 AM. Contact: ###-####. corr made, ok to final. NOTE: basement not sheetrocked, but ric ok and wiring ok since wired as finished basement
|
ELE06-02174
| Electrical Rough-In | 6/22/2006 | 6/22/2006 | 6/22/2006 8:12:54 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 6/22/2006 at 7:22:04 AM. Contact: ###-####. ok to cover u/g only
|
ELE06-02311
| Electrical Rough-In | 6/21/2006 | 6/22/2006 | 6/21/2006 2:55:04 PM | P | CANC |
|
|
Underground inspection; Phone #: ###-#### Inspection cancelled from web by: Wendy Waters
|