ELE12-00654
| ELE-Aging Inspection | 6/22/2016 | 6/22/2016 | 6/23/2016 12:30:32 PM | | DONE |
|
|
Contractor out of buisness. Other ELE has been issued for project
|
ELE09-02259
| ELE-Aging Inspection | 6/22/2016 | 6/22/2016 | 6/23/2016 12:21:24 PM | | DONE |
|
|
Still under construction
|
ELE16-01927
| Rough-In Permanent Service | 6/21/2016 | 6/22/2016 | 6/22/2016 1:52:33 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Emmet Bushman Rough in ok to cover. p/s u/g n ok
|
ELE16-01955
| Electrical Rough-In | 6/22/2016 | 6/22/2016 | 6/22/2016 1:30:48 PM | P | PASS |
|
|
Cal-ground work/trench Phone #: ###-#### Trench from house to detached garage ok to cover
|
ELE15-03896
| Final | 6/22/2016 | 6/22/2016 | 6/22/2016 1:17:17 PM | P | PASS |
|
|
We need a final inspection please. We will have people on site until afternoon. Thank you Ryan Phone #: ###-#### Inspection requested via web by Thomas Jenkins Final ok
|
ELE16-01541
| Final | 6/22/2016 | 6/22/2016 | 6/22/2016 12:54:29 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder 406.5 Recepticles shall be securly mounted. Down wire mold. 334.15 b. NM cable shall be protected from physical damage. Under stairs
|
ELE16-01394
| Final | 6/21/2016 | 6/22/2016 | 6/22/2016 11:49:30 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot 210.8 A 1. Bathroom recepticles shall be GFCI protected. Stool and shower wall receps
|
ELE16-01959
| Rough-In Permanent Service | 6/22/2016 | 6/22/2016 | 6/22/2016 11:28:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok to cover. p/s o/h n ok
|
ELE16-01847
| Final | 6/21/2016 | 6/22/2016 | 6/22/2016 10:27:01 AM | A | PASS |
|
|
Alan// insp. for 2nd floor bedroom Phone #: ###-#### Final ok
|
ELE16-01969
| Electrical Rough-In | 6/21/2016 | 6/22/2016 | 6/22/2016 10:00:56 AM | A | FAIL |
|
|
Please call ahead for access - Zach Phone #: ###-#### 334.30 Securing NM cable within 12" of a box and every 4 1/2ft. 300.4 Wire throu bored holes less than 1 1/4in shall be protected. 300.4 D Cable ran parralel to framing shall be supported 1 1/4in from outside edge of framing. Discussed arc fault protection in bedrooms and tamper resistant outlets.
|
ELE16-00701
| Electrical Rough-In | 6/21/2016 | 6/22/2016 | 6/22/2016 9:04:00 AM | A | PASS |
|
|
Kevin Phone #: ###-#### Equipotential Bonding of hot tub only. Ok to cover
|