ELE17-01533
| Electrical Rough-In | 6/21/2017 | 6/22/2017 | 6/22/2017 1:35:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams...
ceiling grid...ok to cover
|
ELE12-01900
| ELE-Aging Inspection | 6/22/2017 | 6/22/2017 | 6/22/2017 12:52:50 PM | | FAIL |
|
|
still waiting on contractor to get access and schedule...has been contacted more than once
|
ELE12-01902
| ELE-Aging Inspection | 6/22/2017 | 6/22/2017 | 6/22/2017 12:51:49 PM | | FAIL |
|
|
still waiting on contractor to get access and schedule...has been contacted more than once
|
ELE17-01933
| Rough-In Permanent Service | 6/22/2017 | 6/22/2017 | 6/22/2017 12:49:40 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn...
rough ok to cover p/s u/g n ok
|
ELE17-01839
| Rough-In Permanent Service | 6/22/2017 | 6/22/2017 | 6/22/2017 12:27:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn....
rough ok to cover p/s u/g n ok
|
ELE17-00437
| Final | 6/21/2017 | 6/22/2017 | 6/22/2017 11:58:31 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
1) Apt 201...A/C overcurrent protection device is in correct-needs 25A
2) Apt 104...bedroom has no power, bath GFI will not hold, and bedroom outlets show hot/neu reverse
3) Apt 203...outlets in dining room show open ground
|
ELE17-00438
| Final | 6/21/2017 | 6/22/2017 | 6/22/2017 11:58:30 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
ok to final
|
ELE17-01784
| Permanent Service | 6/21/2017 | 6/22/2017 | 6/22/2017 9:58:43 AM | A | PASS |
|
|
Les or ###-#### Phone #: ###-####...
p/s u/g n ok
|
ELE17-01012
| Final | 6/21/2017 | 6/22/2017 | 6/22/2017 9:29:55 AM | A | PASS |
|
|
Late morning if possible thank you! Phone #: ###-#### Inspection requested via web by Kevin Burke....
corrections made...ok to final
|
ELE16-01623
| Final | 6/21/2017 | 6/22/2017 | 6/22/2017 9:11:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan McLaughlin...
job complete...4 head and 2 head LED throughout parking lot...ok to final
|
ELE17-01932
| Electrical Rough-In | 6/22/2017 | 6/22/2017 | 6/22/2017 8:30:14 AM | A | PASS |
|
|
First thing am if possible please. Sheet rockers are ready to rock. Phone #: ###-#### Inspection requested via web by Kerri Hamilton...
wall cover for new recption and meeting area..ok to cover
|
ELE17-01932
| Electrical Rough-In | 6/21/2017 | 6/22/2017 | 6/21/2017 12:26:31 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton Inspection cancelled from web by: Kerri Hamilton
|