FIR18-00432
| INSP-Final Inspection | 6/21/2018 | 6/22/2018 | 6/22/2018 4:02:30 PM | P | PART |
|
|
Partial final inspection for commercial hood fire suppression system complete, operational test has been completed, FIR permit for hood suppression system will remain in issued status until mechanical permit is issued for hood and is in the finaled status.
Dave Phone #: ###-####
|
FIR18-00431
| INSP-Final Inspection | 6/21/2018 | 6/22/2018 | 6/22/2018 4:02:15 PM | P | PART |
|
|
Partial final inspection for commercial hood fire suppression system complete, operational test has been completed, FIR permit for hood suppression system will remain in issued status until mechanical permit is issued for hood and is in the finaled status.
Dave Phone #: ###-####
|
FIR17-00471
| INSP-Final Inspection | 6/21/2018 | 6/22/2018 | 6/22/2018 4:00:00 PM | P | PART |
|
|
Inspection complete for room notification on levels 2 through 5. Fire sprinkler tampers and flow switches complete for levels 1 through 5, point description for standpipe control valves in riser room and level 2 roof top hose valve will be changed to discussed discription. Hood suppression monitoring is complete. Level 1 notification and common area notification and elevator recall to be tested at a later date. Monitoring needs to be verified prior to fire alarm permit being finaled.
Travis Phone #: ###-####
|
BLD17-04518
| FIRE-Final Inspection | 6/22/2018 | 6/22/2018 | 6/22/2018 1:16:28 PM | P | PASS |
|
|
No fire sprinklers, no fire alarms, fire extinguisher is in place with a current inspection tag. Final life fire safety inspection complete.
Phone #: ###-#### Inspection requested via web by Andrew Clark
|
FIR18-00487
| INSP-Final Inspection | 6/22/2018 | 6/22/2018 | 6/22/2018 12:55:57 PM | P | PASS |
|
|
Rough to cover inspection overhead fire sprinkler piping in area of work complete, approved for cover. Reliable fusible link heads with the 401 escutcheons will need to be changed to quick response heads before final inspection, head change will be verified at final inspection.
Rick- please call 30 mins ahead Phone #: ###-####
|
FIR18-00027
| INSP-Supply line flush | 6/22/2018 | 6/22/2018 | 6/22/2018 11:55:51 AM | P | DONE |
|
|
Undergorund main line flush complete for both buildings.
Phone #: ###-#### Inspection requested via web by Christophe Wilson
|
FIR18-00027
| INSP-Sprinkler Rough-in/Hydro | 6/22/2018 | 6/22/2018 | 6/22/2018 11:55:18 AM | A | DONE |
|
|
Hydrostatic test witnessed for both underground main supplies, no pressure loss observed at conractor provided gauges.
|
FIR18-00421
| INSP-Final Inspection | 6/21/2018 | 6/22/2018 | 6/22/2018 11:17:08 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Sam Ball Inspection cancelled from web by: Sam Ball
|
FIR18-00316
| INSP-Final Inspection | 6/21/2018 | 6/22/2018 | 6/22/2018 11:13:57 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Sam Ball Inspection cancelled from web by: Sam Ball
|
BLD17-00665
| FIRE-Final Inspection | 6/21/2018 | 6/22/2018 | 6/22/2018 11:08:26 AM | P | PASS |
|
|
Final life fire safety inspection for scope of work complete.
Mark-please call 30 mins before Phone #: ###-####
|
BLD18-01554
| FIRE-Final Inspection | 6/21/2018 | 6/22/2018 | 6/22/2018 10:41:12 AM | A | PASS |
|
|
No fire sprinklers, no fire alarms, fire extinguisher is in place with a current inspection tag. Final life fire safety inspection complete.
Steve Phone #: ###-####
|
FIR18-00459
| INSP-Sprinkler Rough-in | 6/21/2018 | 6/22/2018 | 6/22/2018 9:43:11 AM | A | PART |
|
|
Rough to cover inspection for overhead fire sprinkler piping on level 2 canopies complete, approved for cover.
Tom Phone #: ###-####
|
FIR17-00586
| INSP-Final Inspection | 6/21/2018 | 6/22/2018 | 6/22/2018 9:17:05 AM | A | PASS |
|
|
Final fire sprinkler inspection for area of work complete.
Phone #: ###-#### Inspection requested via web by Stan Beus
|