Inspections for the day of: Monday, June 22, 2020.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-04505 Electrical Rough-In6/22/20206/22/20206/22/2020 1:59:54 PMPPASS
Corey Hayes is the onsite contact 208.760.0980 Phone #: ###-#### Inspection requested via web by Kevin Perez North underground for ATS, South underground from Storage building to Water pump, North open office area Border tiles only. ok to cover
ELE20-01794 Electrical Rough-In6/22/20206/22/20206/22/2020 1:31:22 PMPPASS
Wall cover downstairs bathroom. Tyson is site contact ###-#### Phone #: ###-#### Inspection requested via web by Shane Lott Down Restrooms only ok ot cover
ELE18-04426 Final6/18/20206/22/20206/22/2020 1:14:50 PMPPASS
Phone #: ###-#### Inspection requested via web by Greg Idsinga final ok
ELE20-00765 Final6/22/20206/22/20206/22/2020 12:56:07 PMPPASS
garage code 4224 Phone #: ###-#### Inspection requested via web by Troy Ballard Final ok
ELE20-01117 Final6/22/20206/22/20206/22/2020 12:07:42 PMPPASS
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk pass
ELE20-01907 Permanent Service6/18/20206/22/20206/22/2020 11:54:36 AMPCANC
Contact: Damonn Barr Phone #: ###-#### Inspection requested via web by Deb Gooden Did not disc. power No Permanent service inspection needed
ELE20-01907 Final6/22/20206/22/20206/22/2020 11:54:26 AMPPASS
Contact: Damonn Barr Phone #: ###-#### Inspection requested via web by Deb Gooden Final ok
ELE20-01907 Electrical Rough-In6/22/20206/22/20206/22/2020 11:54:05 AMPPASS
Contact: Damonn Barr Phone #: ###-#### Inspection requested via web by Deb Gooden Sub panel change only rough in ok
MIS20-00202 ELE-Conference6/22/20206/22/20206/22/2020 10:20:54 AMPDONE
framing, egress window installation, PLM and MEC work done without permit per James Ady Phone #: ###-#### Job site has and Electrical permit to cover scope of work
ELE20-01470 Electrical Rough-In6/20/20206/22/20206/22/2020 10:20:06 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jack Cowan 300.4D Cables shall not be secured within 1 1/4in from face of stud. (Areas through out) 300.4A1 Cables ran through bored hole within 1 1/4in from face of the stud shall have nail plates. (Areas through out) 334.30 Flat cbles shall not be stapled on edge. (Areas through out) 210.52E3 Recep needed on back patio. 210.52 A2 2 receps needed along Living room window wall where concrete has been removed. 300.5B Interior of a conduit ran underground shall be considered a wet location 334.12B4 NM cable shall not be installed in a wet location. Smoke detectors shall be installed.
ELE20-02091 Permanent Service6/19/20206/22/20206/22/2020 9:29:36 AMAPASS
access at left gate Phone #: ###-#### Inspection requested via web by David Nelson p/s o/h rec ok
ELE20-02063 Temporary Service6/19/20206/22/20206/19/2020 3:11:52 PMACANC
Phone #: ###-#### >> Inspection requested via web by Rodney Monroe Inspection cancelled from web by: Rodney Monroe
ELE20-02062 Temporary Service6/19/20206/22/20206/19/2020 3:11:36 PMACANC
Phone #: ###-#### >> Inspection requested via web by Rodney Monroe Inspection cancelled from web by: Rodney Monroe