Inspections for the day of: Monday, June 23, 2008.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00998 Final6/23/20086/23/20086/23/2008 4:49:28 PMPPASS
Phone #: ###-#### Internet Inspection Request from: joe wheeler ok to final, no esc this project
ESC08-00191 General Inspection6/23/20086/23/20086/23/2008 3:35:34 PMPPASS
looked ok
ESC07-01552 Site Preparation6/23/20086/23/20086/23/2008 3:33:56 PMAPASS
looked ok
ELE08-01448 Electrical Rough-In6/20/20086/23/20086/23/2008 3:32:31 PMPPASS
Mike Phone #: ###-#### corrections made, ric ok, no esc this project, walls opened, met contractor
ELE08-01682 Permanent Service6/23/20086/23/20086/23/2008 2:05:24 PMPPASS
200amp service, replaced due to tree that fell over during wind storm on saturday, any questions call Tate @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose p/s o/h rec ok, no esc this project
ELE08-01064 Rough-In Permanent Service6/23/20086/23/20086/23/2008 1:01:48 PMPFAIL
Neil ###-#### called, left message, left correction notice, BCC all ri shall be done, all make-up shall be done, NEC 210.52(H) hallway over 10' shall have receptacle outlet installed, 210.(A)(1),(2) wall over 2' shall have receptacle installed, 314.25boxes shall have cover installed- up lighting, 300.4(A)(1) nailplate shall be installed if edge of bored hole less than 1/14" from edge of framing member, 334.30 shall secure nm cable within 12" of panel
ELE08-00039 Rough-In Permanent Service6/20/20086/23/20086/23/2008 10:13:05 AMAPASS
Ready for bonding inspection Phone #: ###-#### Internet Inspection Request from: gary batten ri ok, p/s o/h rec ok, no esc this project
ELE08-01671 Rough-In Permanent Service6/20/20086/23/20086/23/2008 10:09:29 AMAPASS
Tom- this is for a garage outlet and service Phone #: ###-#### p/s o/h n ok, no esc this project, ri ok, called, left message about door light before final
ELE08-01651 Permanent Service6/20/20086/23/20086/23/2008 9:16:24 AMAPASS
Phone #: ###-#### Internet Inspection Request from: BRENDA HURST p/s u/g n ok, no esc this project
ELE08-00693 Final6/23/20086/23/20086/23/2008 8:46:05 AMAFAIL
Hello the house is ready to final the contractor probally be there if any questions give me a call Don ###-#### Thanks Phone #: ###-#### Internet Inspection Request from: Don Lustig called contractor, left correction notice on panel, BCC all u/g shall be seen before cover,garage and post lite, no violations shall be retained, all fixtures shall be installed, NEC 422.31(B) water heater shall be provided with disconnect, 110.3(B) listed equipment shall be installed per mfgr's instructions (polarity for outlet)
ELE08-00674 Final6/23/20086/23/20086/23/2008 8:04:23 AMAPASS
looked at sign, ok to final, no esc this project