Inspections for the day of: Tuesday, June 23, 2009.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-00411 ELE-Aging Inspection6/23/20096/23/20097/1/2009 1:51:28 PM CANC
ELE09-00410 ELE-Aging Inspection6/23/20096/23/20096/30/2009 3:04:05 PM CANC
ELE08-03104 Electrical Rough-In6/23/20096/23/20096/24/2009 8:57:25 AMPPASS
duke - late afternoon please Phone #: ###-#### ceilings ok
ELE09-00046 Final6/23/20096/23/20096/24/2009 8:49:34 AMPPASS
Please call Nate Peterson-###-#### Internet Inspection Request from: Sarah Bastian survey for 1.0 water bond H&C, and 7 can light trims card signed
ELE09-01047 Permanent Service6/23/20096/23/20096/23/2009 4:36:06 PMPFAIL
john Phone #: ###-#### corr met contr 230.2 only one p/s allowed on building unless all NEC requirements are met as code noted states
ELE09-00531 Final6/23/20096/23/20096/23/2009 3:33:38 PMPPASS
Alan Phone #: ###-#### ok
ELE09-00532 Final6/23/20096/23/20096/23/2009 3:33:18 PMPPASS
Alan Phone #: ###-#### ok
ELE09-01088 Temporary Service6/23/20096/23/20096/23/2009 2:42:06 PMPFAIL
Terry Phone #: ###-#### corr called 200.2(B) terminate GEC to neutral bus, needs conn for GEC
ELE09-01090 Rough-In Permanent Service6/22/20096/23/20096/23/2009 2:18:41 PMAFAIL
rod - late morning please Phone #: ###-#### corr for r/i 314,16 box fill bath recept, 210.52(D) & 210-11(C)(3) needs 20 bath circuit, 250.56 needs 2 grd rods see added p/s request
ELE09-01090 Permanent Service6/23/20096/23/20096/23/2009 2:16:44 PMPPASS
rod - late morning please Phone #: ###-#### p/s o/h rec. ok
ELE09-00151 Electrical Rough-In6/23/20096/23/20096/23/2009 1:42:03 PMPPASS
mike Phone #: ###-#### 1st floor walls and hard ceilings anop
ELE09-01094 Electrical Rough-In6/22/20096/23/20096/23/2009 1:07:51 PMAFAIL
Thank you. Phone #: ###-#### Internet Inspection Request from: Rhonda Yoast
corr called 210.52(B) shall remove switch and light from SABC formal din rm, note 410.2 definition of closet storage space , and location of fixtures, 110.3(B) gas rangr recept on exhaust/micro wave circuit do manufacture's instructions allow it?312.5 bushings where low voltage enters cabinet,
B C C shall provide city approved plans at job site and request p/s inspection not just r/i
ELE09-01096 Final6/23/20096/23/20096/23/2009 10:54:29 AMPCANC
mike - late afternoon please Phone #: ###-#### will meet contr 06-24-09 8:00 am
ELE09-01089 Electrical Rough-In6/22/20096/23/20096/23/2009 10:51:39 AMAPART
JOB SITE CONTACT IS RICK ###-#### Phone #: ###-#### Internet Inspection Request from: JENNY EMEL walls and high ceiling
ELE09-00912 Permanent Service6/22/20096/23/20096/23/2009 10:21:37 AMAFAIL
troy Phone #: ###-#### job not ready needs 2" mast and all grding complete called
ELE09-01071 Electrical Rough-In6/23/20096/23/20096/23/2009 10:09:18 AMPCANC
george Phone #: ###-#### contr called he covered u/g before inspection, needs to uncover
ELE09-01017 Electrical Rough-In6/22/20096/23/20096/23/2009 10:02:13 AMAPART
Robert Phone #: ###-#### conference
ELE09-01036 Electrical Rough-In6/23/20096/23/20096/23/2009 10:01:42 AMPPASS
mike Phone #: ###-#### r/i ok kitchen
ELE08-02384 Final6/22/20096/23/20096/23/2009 10:00:58 AMACANC
Need a final on this job. Please call Roger Reynolds, at ###-####. With Questions. Thanks Phone #: ###-#### Internet Inspection Request from: Debby Ellis
contr called and canceled
ELE09-01076 Conference6/18/20096/23/20096/23/2009 9:10:12 AMAPASS
Jared ###-#### ok
ELE09-00885 Permanent Service6/22/20096/23/20096/23/2009 8:45:04 AMAPASS
Travis Phone #: ###-#### still needs r/i , called no access p/s u/g rec. ok
ELE09-01091 Electrical Rough-In6/22/20096/23/20096/23/2009 8:17:06 AMAPASS
john Phone #: ###-#### - please call 1/2 hr prior ok , check pendent lights above tub at final, for 8ft above tub rim
ELE09-01042 Final6/22/20096/23/20096/23/2009 7:48:57 AMAPASS
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten ok