ELE09-00411
| ELE-Aging Inspection | 6/23/2009 | 6/23/2009 | 7/1/2009 1:51:28 PM | | CANC |
|
|
|
ELE09-00410
| ELE-Aging Inspection | 6/23/2009 | 6/23/2009 | 6/30/2009 3:04:05 PM | | CANC |
|
|
|
ELE08-03104
| Electrical Rough-In | 6/23/2009 | 6/23/2009 | 6/24/2009 8:57:25 AM | P | PASS |
|
|
duke - late afternoon please Phone #: ###-#### ceilings ok
|
ELE09-00046
| Final | 6/23/2009 | 6/23/2009 | 6/24/2009 8:49:34 AM | P | PASS |
|
|
Please call Nate Peterson-###-#### Internet Inspection Request from: Sarah Bastian survey for 1.0 water bond H&C, and 7 can light trims card signed
|
ELE09-01047
| Permanent Service | 6/23/2009 | 6/23/2009 | 6/23/2009 4:36:06 PM | P | FAIL |
|
|
john Phone #: ###-#### corr met contr 230.2 only one p/s allowed on building unless all NEC requirements are met as code noted states
|
ELE09-00531
| Final | 6/23/2009 | 6/23/2009 | 6/23/2009 3:33:38 PM | P | PASS |
|
|
Alan Phone #: ###-#### ok
|
ELE09-00532
| Final | 6/23/2009 | 6/23/2009 | 6/23/2009 3:33:18 PM | P | PASS |
|
|
Alan Phone #: ###-#### ok
|
ELE09-01088
| Temporary Service | 6/23/2009 | 6/23/2009 | 6/23/2009 2:42:06 PM | P | FAIL |
|
|
Terry Phone #: ###-#### corr called 200.2(B) terminate GEC to neutral bus, needs conn for GEC
|
ELE09-01090
| Rough-In Permanent Service | 6/22/2009 | 6/23/2009 | 6/23/2009 2:18:41 PM | A | FAIL |
|
|
rod - late morning please Phone #: ###-#### corr for r/i 314,16 box fill bath recept, 210.52(D) & 210-11(C)(3) needs 20 bath circuit, 250.56 needs 2 grd rods see added p/s request
|
ELE09-01090
| Permanent Service | 6/23/2009 | 6/23/2009 | 6/23/2009 2:16:44 PM | P | PASS |
|
|
rod - late morning please Phone #: ###-#### p/s o/h rec. ok
|
ELE09-00151
| Electrical Rough-In | 6/23/2009 | 6/23/2009 | 6/23/2009 1:42:03 PM | P | PASS |
|
|
mike Phone #: ###-#### 1st floor walls and hard ceilings anop
|
ELE09-01094
| Electrical Rough-In | 6/22/2009 | 6/23/2009 | 6/23/2009 1:07:51 PM | A | FAIL |
|
|
Thank you. Phone #: ###-#### Internet Inspection Request from: Rhonda Yoast corr called 210.52(B) shall remove switch and light from SABC formal din rm, note 410.2 definition of closet storage space , and location of fixtures, 110.3(B) gas rangr recept on exhaust/micro wave circuit do manufacture's instructions allow it?312.5 bushings where low voltage enters cabinet, B C C shall provide city approved plans at job site and request p/s inspection not just r/i
|
ELE09-01096
| Final | 6/23/2009 | 6/23/2009 | 6/23/2009 10:54:29 AM | P | CANC |
|
|
mike - late afternoon please Phone #: ###-#### will meet contr 06-24-09 8:00 am
|
ELE09-01089
| Electrical Rough-In | 6/22/2009 | 6/23/2009 | 6/23/2009 10:51:39 AM | A | PART |
|
|
JOB SITE CONTACT IS RICK ###-#### Phone #: ###-#### Internet Inspection Request from: JENNY EMEL walls and high ceiling
|
ELE09-00912
| Permanent Service | 6/22/2009 | 6/23/2009 | 6/23/2009 10:21:37 AM | A | FAIL |
|
|
troy Phone #: ###-#### job not ready needs 2" mast and all grding complete called
|
ELE09-01071
| Electrical Rough-In | 6/23/2009 | 6/23/2009 | 6/23/2009 10:09:18 AM | P | CANC |
|
|
george Phone #: ###-#### contr called he covered u/g before inspection, needs to uncover
|
ELE09-01017
| Electrical Rough-In | 6/22/2009 | 6/23/2009 | 6/23/2009 10:02:13 AM | A | PART |
|
|
Robert Phone #: ###-#### conference
|
ELE09-01036
| Electrical Rough-In | 6/23/2009 | 6/23/2009 | 6/23/2009 10:01:42 AM | P | PASS |
|
|
mike Phone #: ###-#### r/i ok kitchen
|
ELE08-02384
| Final | 6/22/2009 | 6/23/2009 | 6/23/2009 10:00:58 AM | A | CANC |
|
|
Need a final on this job. Please call Roger Reynolds, at ###-####. With Questions. Thanks Phone #: ###-#### Internet Inspection Request from: Debby Ellis contr called and canceled
|
ELE09-01076
| Conference | 6/18/2009 | 6/23/2009 | 6/23/2009 9:10:12 AM | A | PASS |
|
|
Jared ###-#### ok
|
ELE09-00885
| Permanent Service | 6/22/2009 | 6/23/2009 | 6/23/2009 8:45:04 AM | A | PASS |
|
|
Travis Phone #: ###-#### still needs r/i , called no access p/s u/g rec. ok
|
ELE09-01091
| Electrical Rough-In | 6/22/2009 | 6/23/2009 | 6/23/2009 8:17:06 AM | A | PASS |
|
|
john Phone #: ###-#### - please call 1/2 hr prior ok , check pendent lights above tub at final, for 8ft above tub rim
|
ELE09-01042
| Final | 6/22/2009 | 6/23/2009 | 6/23/2009 7:48:57 AM | A | PASS |
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten ok
|