Inspections for the day of: Thursday, June 23, 2011.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02423 Electrical Rough-In6/22/20116/23/20116/23/2011 3:39:30 PMPPASS
Jason B3 L2 & L4 soffit cover Phone #: ###-#### >> Inspection requested via web by Sean DeLacy soffits anop
ELE11-01339 Temporary Service6/23/20116/23/20116/23/2011 2:26:21 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson t/s u/g n ok
ELE11-01340 Temporary Service6/23/20116/23/20116/23/2011 2:24:42 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson t/s u/g n ok
ELE11-01307 Rough-In Permanent Service6/23/20116/23/20116/23/2011 1:42:55 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson ri ok, p/s u/g n ok
ELE11-01295 Final6/23/20116/23/20116/23/2011 1:03:07 PMPFAIL
please final Phone #: ###-#### >> Inspection requested via web by David Mackey called, told to clean up panel schedules, strap mc cable, plug openings in boxes
ELE11-01341 Electrical Rough-In6/23/20116/23/20116/23/2011 12:45:18 PMPFAIL
Russ Phone #: ###-#### please call 30 min before going out called left message, left correction notice, NEC 300.4(D) edge of cable shall be 1 1/4" from edge of framing member and not in stud valley, 330.30(A) mc shall be supported within 12" of box, 358.30(A) shall support emt within 3' of box, 250.86 shall ground metal boxes, 110.12(A) shall close unused openings, BCC no violations shall be retained-ceilings shall be per code
ELE11-01315 Electrical Rough-In6/22/20116/23/20116/23/2011 10:35:49 AMAPASS
Phone #: ###-#### >> Inspection requested via web by TRAVIS WARFIELD corrections made, ri ok
ELE11-01010 Electrical Rough-In6/22/20116/23/20116/23/2011 9:44:22 AMAPASS
cable heat-tile floor--Calvin Phone #: ###-#### ok cover floor heat
ELE11-01323 Temporary Service6/22/20116/23/20116/23/2011 9:15:57 AMAPASS
Cal Phone #: ###-#### t/s u/g n ok
ELE11-00775 Final6/22/20116/23/20116/23/2011 8:48:39 AMAFAIL
GARAGE CODE 1968 Phone #: ###-#### >> Inspection requested via web by Bob Glenn called, left correction notice, IEC too many incandescent light bulbs, NEC 250.68(A) shall provide access point to grounding electrode connection
ELE10-02040 ELE-Aging Inspection6/23/20116/23/20116/23/2011 7:23:03 AM DONE
still under construction
ELE10-01827 ELE-Aging Inspection6/23/20116/23/20116/23/2011 7:22:24 AM DONE
still under construction