ELE08-02423
| Electrical Rough-In | 6/22/2011 | 6/23/2011 | 6/23/2011 3:39:30 PM | P | PASS |
|
|
Jason B3 L2 & L4 soffit cover Phone #: ###-#### >> Inspection requested via web by Sean DeLacy soffits anop
|
ELE11-01339
| Temporary Service | 6/23/2011 | 6/23/2011 | 6/23/2011 2:26:21 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson t/s u/g n ok
|
ELE11-01340
| Temporary Service | 6/23/2011 | 6/23/2011 | 6/23/2011 2:24:42 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson t/s u/g n ok
|
ELE11-01307
| Rough-In Permanent Service | 6/23/2011 | 6/23/2011 | 6/23/2011 1:42:55 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson ri ok, p/s u/g n ok
|
ELE11-01295
| Final | 6/23/2011 | 6/23/2011 | 6/23/2011 1:03:07 PM | P | FAIL |
|
|
please final Phone #: ###-#### >> Inspection requested via web by David Mackey called, told to clean up panel schedules, strap mc cable, plug openings in boxes
|
ELE11-01341
| Electrical Rough-In | 6/23/2011 | 6/23/2011 | 6/23/2011 12:45:18 PM | P | FAIL |
|
|
Russ Phone #: ###-#### please call 30 min before going out called left message, left correction notice, NEC 300.4(D) edge of cable shall be 1 1/4" from edge of framing member and not in stud valley, 330.30(A) mc shall be supported within 12" of box, 358.30(A) shall support emt within 3' of box, 250.86 shall ground metal boxes, 110.12(A) shall close unused openings, BCC no violations shall be retained-ceilings shall be per code
|
ELE11-01315
| Electrical Rough-In | 6/22/2011 | 6/23/2011 | 6/23/2011 10:35:49 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by TRAVIS WARFIELD corrections made, ri ok
|
ELE11-01010
| Electrical Rough-In | 6/22/2011 | 6/23/2011 | 6/23/2011 9:44:22 AM | A | PASS |
|
|
cable heat-tile floor--Calvin Phone #: ###-#### ok cover floor heat
|
ELE11-01323
| Temporary Service | 6/22/2011 | 6/23/2011 | 6/23/2011 9:15:57 AM | A | PASS |
|
|
Cal Phone #: ###-#### t/s u/g n ok
|
ELE11-00775
| Final | 6/22/2011 | 6/23/2011 | 6/23/2011 8:48:39 AM | A | FAIL |
|
|
GARAGE CODE 1968 Phone #: ###-#### >> Inspection requested via web by Bob Glenn called, left correction notice, IEC too many incandescent light bulbs, NEC 250.68(A) shall provide access point to grounding electrode connection
|
ELE10-02040
| ELE-Aging Inspection | 6/23/2011 | 6/23/2011 | 6/23/2011 7:23:03 AM | | DONE |
|
|
still under construction
|
ELE10-01827
| ELE-Aging Inspection | 6/23/2011 | 6/23/2011 | 6/23/2011 7:22:24 AM | | DONE |
|
|
still under construction
|