Inspections for the day of: Monday, June 23, 2014.
Number of inspections: 32
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-02473 Pressure Test6/23/20146/23/20146/23/2014 3:39:26 PMPPASS
Jason w/TML is requesting an AM and will call you, thank you Phone #: ###-#### Inspection requested via web by Michele LaMott-20 lb gas test pass
MEC14-02473 Rough-in6/23/20146/23/20146/23/2014 3:38:07 PMPPASS
Jason w/TML is requesting an AM and will call you, thank you Phone #: ###-#### Inspection requested via web by Michele LaMott-20 lb gas test pass
MEC14-02213 Final6/20/20146/23/20146/23/2014 3:37:08 PMPPASS
Phone #: ###-#### Inspection requested via web by Karl Hestekin
MEC14-02225 Rough-in6/23/20146/23/20146/23/2014 2:48:38 PMPFAIL
Phone #: ###-#### Inspection requested via web by April Thomas-Missing supply in living room per manual-j and need to nailplate condensate.
MEC14-02225 Pressure Test6/23/20146/23/20146/23/2014 2:46:27 PMPFAIL
Phone #: ###-#### Inspection requested via web by April Thomas-Pressure test fail and need to use approved nailplates for gastite.
MEC14-01621 Final6/19/20146/23/20146/23/2014 1:47:31 PMPPASS
Call Jason @ ###-#### with any inspection issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
MEC14-01370 Final6/20/20146/23/20146/23/2014 1:41:02 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC14-01431 Final6/20/20146/23/20146/23/2014 1:40:46 PMPNH
Call Jason @ ###-#### with any inspection issues. Phone #: ###-#### Inspection requested via web by Angie Maguire-No access due to flrs
MEC14-02459 Rough-in6/18/20146/23/20146/23/2014 1:34:30 PMPPASS
Inspection requested via web by Jason Robinson
MEC14-02528 Final6/23/20146/23/20146/23/2014 1:28:03 PMPPART
Mid to late afternoon, will need flue test witnessed. Phone #: ###-#### Inspection requested via web by April Thomas-Test on flue pass
PLM14-01737 Sprinkler (Final)6/23/20146/23/20146/23/2014 1:18:38 PMPPASS
Phone #: ###-#### Inspection requested via web by Darrell Roark
PLM14-01740 Sprinkler (Final)6/23/20146/23/20146/23/2014 1:18:22 PMPPASS
Phone #: ###-#### Inspection requested via web by Darrell Roark
PLM14-01213 Final6/23/20146/23/20146/23/2014 1:14:40 PMPPASS
Ron Phone #: ###-####
PLM13-03408 Final6/23/20146/23/20146/23/2014 1:04:21 PMPNR
Not ready
MEC14-00472 Final6/23/20146/23/20146/23/2014 1:01:18 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
PLM13-03408 Final6/20/20146/23/20146/23/2014 12:52:59 PMPNR
if questions call Iso @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann///Per Eric Not Ready
MEC14-02461 Rough-in6/18/20146/23/20146/23/2014 12:28:30 PMPFAIL
Inspection requested via web by Jason Robinson-Not ready.
PLM14-01701 Sprinkler (Final)6/23/20146/23/20146/23/2014 12:12:01 PMPPASS
Teresa Phone #: ###-####
MEC14-02496 Pressure Test6/20/20146/23/20146/23/2014 11:24:59 AMANR
Please Call Dwight ###-#### @ Jims Heating Prior To Inspection.We Are Starting The Job At 8 AM And Should Be Ready By 11AM Thank You Phone #: ###-#### Inspection requested via web by Manuel Acuna-Not ready
MEC14-02353 Rough-in6/20/20146/23/20146/23/2014 11:19:10 AMAFAIL
renee ###-####-Need heat sheild
MEC13-01180 Final6/20/20146/23/20146/23/2014 11:18:36 AMAPASS
call before you go meet you there 30 minutes notice ###-#### Phone #: ###-#### Inspection requested via web by Rene Neumeyer
PLM14-01598 Plumbing Rough-in6/20/20146/23/20146/23/2014 10:03:40 AMAPASS
Rough-in inspection of bathroom addition downstairs. If nobody is at home, back door should be unlocked. Phone #: ###-#### Inspection requested via web by James Solosabal
PLM14-01707 Final6/20/20146/23/20146/23/2014 9:45:33 AMAPASS
MEC14-02112 Pressure Test6/20/20146/23/20146/23/2014 9:14:51 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino-gas test fail
MEC14-02112 Rough-in6/20/20146/23/20146/23/2014 9:13:49 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino-2nd flr return in stairwell is undersized per the manual-j and bath exhaust 2nd flr needs hooked up.
MEC14-01601 Final6/20/20146/23/20146/23/2014 8:46:23 AMAPASS
Call Josh with questions and garage code at ###-####
or Alpine Fireplace at ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
PLM14-01675 Final6/16/20146/23/20146/23/2014 8:44:42 AMAFAIL
Our technician will advise customer of inspection date. Please call customer John Nice at ###-#### with an ETA. Thanks! Phone #: ###-#### Inspection requested via web by Kerrie Simpson-Need min of a 1" airgap above drain on softner discharge.
MEC14-01509 Final6/20/20146/23/20146/23/2014 8:32:34 AMAPASS
Call Josh at ###-#### for questions and garage access code
or Alpine Fireplace at ###-####
Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC14-02437 Rough-in6/20/20146/23/20146/23/2014 8:24:10 AMAFAIL
Phone #: ###-#### Inspection requested via web by Dan Otero-Gas shutoff valve needs to be located in the same room as the appliance and need to support horizontal portion of vent.
PLM14-01756 Plumbing Rough-in6/22/20146/23/20146/23/2014 8:07:44 AMAPASS
Phone #: ###-#### Inspection requested via web by David Stephenson
MEC14-01412 Final6/18/20146/23/20146/23/2014 8:00:47 AMAPASS
Call Clint wiith questions and garage code at ###-####
or Alpine Fireplace at ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
PLM14-01736 Plumbing Rough-in6/20/20146/23/20146/20/2014 3:26:23 PMACANC
>> Inspection requested via web by Erin Whiting Inspection cancelled from web by: Erin Whiting