Inspections for the day of: Friday, June 23, 2017.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrandon Shaw
TitleBLD-COM/RES INSPECTOR
Phone #208-954-9358
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD17-01351 BLD-Footing6/23/20176/23/20176/23/2017 4:55:23 PMPPASS
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
BLD17-01352 BLD-Footing6/23/20176/23/20176/23/2017 4:55:13 PMPPASS
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
BLD17-00624 BLD-Foundation6/23/20176/23/20176/23/2017 4:54:54 PMPPASS
As late as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
BLD17-00776 BLD-Footing6/22/20176/23/20176/23/2017 4:54:40 PMPPASS
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo
BLD17-00584 BLD-Wall Bracing6/23/20176/23/20176/23/2017 2:57:40 PMPFAIL
Rollo Phone #: ###-####
OK to wrap exterior and install windows
MIS17-00201 BLD-Conference6/23/20176/23/20176/23/2017 2:13:47 PMPPEND
took out drinking fountain w/o permits see Carl M if you have questions
No one available at time of inspection, left a Stop Work Order.
BLD17-00528 BLD-Framing/Rough-in6/23/20176/23/20176/23/2017 1:23:22 PMPFAIL
Provide Truss Engineering
OK to insulate
BLD16-04303 BLD-Final6/23/20176/23/20176/23/2017 1:22:02 PMPPASS
Phone #: ###-#### Inspection requested via web by Braxton Hansen
BLD16-04303 DOC - Permit Finaled6/23/20176/23/20176/23/2017 1:21:51 PMPPASS
BLD16-04130 BLD-Energy code compliance6/22/20176/23/20176/23/2017 12:12:17 PMAPASS
Framing corrections made, OK to cover
BLD16-04247 BLD-Final6/22/20176/23/20176/23/2017 12:11:20 PMAPASS
Mark Phone #: ###-####
BLD16-04247 DOC - Permit Finaled6/23/20176/23/20176/23/2017 12:11:11 PMPPASS
BLD16-04247 DOC - Permit Finaled6/23/20176/23/20176/23/2017 12:11:02 PMPPASS
BLD16-04280 BLD-Wall Bracing6/21/20176/23/20176/23/2017 11:16:24 AMACANC
Noah Phone #: ###-####
BLD17-02002 BLD-Final6/19/20176/23/20176/23/2017 10:34:43 AMAPASS
Please call ahead for access - Cody Phone #: ###-####
BLD15-03423 BLD-Energy code compliance6/22/20176/23/20176/23/2017 10:34:42 AMAPART
Tower B, Floors 3 thru 7 Corridor Insulation and Barriers.
BLD17-02002 DOC - Permit Finaled6/23/20176/23/20176/23/2017 10:34:29 AMPPASS
BLD16-04004 BLD-Ceiling Grid Inspection6/23/20176/23/20176/23/2017 9:43:07 AMAPASS
Early a.m. ceiling grid inspection level one and level to call Adam thank you Akj Phone #: ###-#### Inspection requested via web by Adam Johnson
BLD16-03246 BLD-Foundation6/22/20176/23/20176/23/2017 9:42:30 AMAPASS
Basement... as early as possible // jared Phone #: ###-####
BLD17-00659 BLD-Final6/22/20176/23/20176/22/2017 1:36:59 PMAPASS
Mike-please call to meet for access Phone #: ###-####