Inspections for the day of: Tuesday, June 24, 2008.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM08-00911 Final6/24/20086/24/20086/24/2008 4:38:57 PMPPART
Scheduled by a contractor via Hello! on 6/24/2008 at 6:47:32 AM. Contact: ###-####.-will final house when a water & sewer permit is issued.
PLM08-01495 Water and/or Sewer6/24/20086/24/20086/24/2008 3:47:39 PMPPART
Clint ###-#### need to step water service up to 1" & use approved material, sewer pass.
PLM07-00883 Sprinkler (Final)6/24/20086/24/20086/24/2008 3:12:18 PMPPART
adi Phone #: ###-####-cannot use a stop & waste, pvb needs tested & certified.
PLM08-01344 Final6/24/20086/24/20086/24/2008 2:14:15 PMPPASS
gene Phone #: ###-####
PLM08-01481 Sprinkler (Final)6/24/20086/24/20086/24/2008 1:58:11 PMPPASS
PLM08-01491 Water and/or Sewer6/24/20086/24/20086/24/2008 1:56:26 PMPPASS
Brett Phone #: ###-####
PLM08-01491 DOC - Permit Finaled6/24/20086/24/20086/24/2008 1:56:14 PMPPASS
Brett Phone #: ###-####
PLM07-03599 Other6/24/20086/24/20086/24/2008 1:32:42 PMPPART
this was a conferance on running dwv.
PLM08-00768 Plumbing Rough-in6/24/20086/24/20086/24/2008 12:26:47 PMPPASS
final on 5-44-08 was a rough-in inspection, rough-in pass.
PLM06-02370 Plumbing Rough-in6/23/20086/24/20086/24/2008 12:17:28 PMAFAIL
GREG Phone #: ###-####- fix reverse grade on dwv, softner drain needs to be 3/4", need soft water to washer box, need 1 soft cold & 1 hard cold to kitchen sink, retest dwv & water when corrections are complete.
ESC05-00045 General Inspection6/24/20086/24/20086/24/2008 11:00:02 AMAPASS
bmp's in order
PLM08-01484 Sprinkler (Final)6/23/20086/24/20086/24/2008 10:57:40 AMAFAIL
Kelley Putzier ###-####-need to use approved material up to pvb, need a union downstream of pvb, need to grade line back to draindown valve.
PLM08-01481 Sprinkler (Final)6/24/20086/24/20086/24/2008 9:47:13 AMAFAIL
need to turn tee to horizontal to keep drain & shutoff as low as possible to keep from freezing, finish tie in, dbca needs tested & certified.
PLM07-03599 Other6/23/20086/24/20086/24/2008 9:39:38 AMACANC
Doc- confrence Phone #: ###-####
PLM08-01341 Other6/23/20086/24/20086/24/2008 9:23:16 AMAPART
9:00 am-need to install rpba for premis protection, need to install rpba on water supply to vacuum pumps, (suite b) need to install rpba on hot & cold supply to dishwasher & hook drain up to dishwasher tail piece, supply floor sink for rpba's, need thermal expansion tank, (suite d) need to isolate all dental chairs with rpba's.
PLM05-00805 Final6/24/20086/24/20086/24/2008 8:56:07 AMAPASS
this permit was for ground work only. home owner greg abel will finish rough-in & trim.
PLM08-01481 Water and/or Sewer6/23/20086/24/20086/24/2008 8:10:29 AMACANC
Please call Eddie with any questions Phone #: ###-#### Internet Inspection Request from: Nichole Collingwood