Inspections for the day of: Wednesday, June 24, 2015.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01035 ELE-Aging Inspection6/24/20156/24/20156/25/2015 7:44:21 AM DONE
too busy
ELE15-01872 Rough-In Permanent Service6/23/20156/24/20156/24/2015 3:02:13 PMPPASS
extended service conductors in to home j-box on west side just passed backdoor under home Phone #: ###-#### Inspection requested via web by Thomas wilson r/i ok p/s u/g rec ok
ELE15-01904 Rough-In Permanent Service6/24/20156/24/20156/24/2015 2:13:22 PMPFAIL
Phone #: ###-#### Inspection requested via web by steve cooper 210.52(D)-in dwelling units at least one receptacle shall be installed in bathrooms within 3 foot of each basin. 300.4-not less than 11/4" from bored holes to edge of stud.
ELE13-03438 Permanent Service6/24/20156/24/20156/24/2015 1:36:12 PMPCANC
Please contact Jeremiah Goins on site at ###-#### Phone #: ###-#### Inspection requested via web by Deb Gooden needed r/i for performance test completion
ELE13-03438 Electrical Rough-In6/24/20156/24/20156/24/2015 1:35:52 PMPPASS
Please contact Jeremiah Goins on site at ###-#### Phone #: ###-#### Inspection requested via web by Deb Gooden performance test completed (p/s already passed)
ELE13-03438 Electrical Rough-In6/24/20156/24/20156/24/2015 1:34:13 PMPPASS
Please contact Jeremiah Goins on site at ###-#### Phone #: ###-#### Inspection requested via web by Deb Gooden performance test completed
GCE15-00097 GCE-Rough-In6/24/20156/24/20156/24/2015 12:44:26 PMPPASS
Shawn ###-#### - underground and grounding for shop/garage 2" pvc in slab and ground rods r/i ok
GCE15-00098 GCE-Rough-In6/24/20156/24/20156/24/2015 12:43:30 PMPPASS
Shawn ###-#### - underground and grounding for shop/garage r/i ok 2" pvc in slab and ground rods
ELE15-01472 Electrical Rough-In6/23/20156/24/20156/24/2015 11:10:30 AMAPASS
Please provide us with a ceiling inspection.
Joel Hudson Phone #: ###-#### Inspection requested via web by Kevin Perez r/i t bar ceilings ok to cover
ELE15-00956 Final6/23/20156/24/20156/24/2015 10:54:33 AMAPASS
Shane is the contact his cell no. is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates final ok
GCE15-00067 GCE-Final6/23/20156/24/20156/24/2015 10:10:49 AMAFAIL
Ben ###-#### 110.24(A)- fault current needs date also. Exterior light pole or sign bases not poured and no wire installed in raceways??
GCE14-00207 GCE-Permanent Service6/23/20156/24/20156/24/2015 9:27:54 AMAPASS
Kevin ###-#### - service insp. p/s u/g n ok
ELE14-02710 Final6/23/20156/24/20156/24/2015 8:25:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Thomas Jenkins final ok